Evaluation of clinical performance and safety for the rechargeable InterStim Micro device in overactive bladder subjects: 6‐month results from the global postmarket ELITE study

Author:

Goudelocke Colin1ORCID,Xavier Keith2,Pecha Barry3,Burgess Kimberly4,Perrouin‐Verbe Marie‐A.5,Krlin Ryan6,Michaels Jodi7,Shah Sagar8,Peyronnet Benoît9,Zaslau Stanley10,Champs Mylène11,Papi Bianca11,Bittner Katie11,Elterman Dean12ORCID,Nitti Victor13

Affiliation:

1. Department of Urology Ochsner Medical Center New Orleans Louisiana USA

2. Urology Partners of North Texas Arlington Texas USA

3. First Urology Jeffersonville Indiana USA

4. Prisma Health Greenville South Carolina USA

5. Department of Urology, Centre Hospitalier Universitaire de Nantes Nantes Université Nantes France

6. Department of Urology Louisiana State University Health Sciences Center New Orleans Louisiana USA

7. Center for Continence Care, Minnesota Urology Woodbury Minnesota USA

8. East Coast Institute for Research LLC Jacksonville Florida USA

9. Department of Urology Centre Hospitalier Universitaire de Rennes Rennes France

10. Department of Urology West Virginia University Morgantown West Virginia USA

11. Medtronic Minneapolis Minnesota USA

12. Division of Urology University of Toronto Toronto Canada

13. Department of Urology and Obstetrics and Gynecology, Division of Female Pelvic Medicine and Reconstructive Surgery University of California Los Angeles Los Angeles California USA

Abstract

AbstractAimsSacral neuromodulation (SNM) is an advanced therapy option for the treatment of overactive bladder (OAB), nonobstructive urinary retention, and fecal incontinence. The aim of this ongoing prospective, multicenter, global, postmarket study is to confirm safety and clinical performance of the InterStimTM Micro system for SNM in all indications. Reported here are the results for the OAB cohort through 6‐month follow‐up.MethodsEligible OAB subjects that had a successful therapy evaluation were enrolled after implant of an InterStim Micro implantable pulse generator (IPG). Subjects completed voiding diaries and the Overactive Bladder Quality of Life questionnaire (OAB‐q) at baseline and follow‐up visits occurring at 3 months and 6 months postimplant. Safety was evaluated as device‐, procedure‐, or therapy‐related adverse events. The primary objective for the OAB cohort was to demonstrate an improvement in OAB‐q Health Related Quality of Life (HRQL) total score at 3 months postimplant compared to baseline.ResultsSixty‐eight OAB subjects were enrolled and implanted with an InterStim Micro IPG. Of those, 67 and 66 subjects completed the 3‐ and 6‐month follow‐up visits, respectively. The OAB‐q HRQL demonstrated a statistically significant improvement from baseline to 3‐month follow‐up with an average increase of 33 ± 24 points (n = 67, p < 0.001). The change was also observed at 6‐months with an average increase of 31 ± 23 points (n = 65) compared to baseline. Eighty‐two percent of subjects achieved the minimally important difference in HRQL score at 3‐ and 6‐month, respectively, with a change of 10 points or greater. The majority of subjects reported that their bladder condition was better at 3‐month (92.5%, 62/67) and 6‐month (89%, 59/66) compared to before they were treated with SNM therapy delivered by the InterStim Micro system. For subjects with urgency urinary incontinence (UUI), the average change from baseline to follow‐up in UUI episodes/day was −3.6 (95% CI: −4.7, −2.6; n = 62) at 3‐month and −3.7 (95% CI: −4.7, −2.7; n = 61) at 6‐month. Among subjects with urgency‐frequency (UF), the average change from baseline to follow up in voids/day was −4.5 (95% CI: −6.3, −2.7; n = 52) at 3‐months and −4.4 (95% CI: −6.0, −2.7; n = 52) at 6‐month. The cumulative incidence of device‐, procedure‐, or therapy‐ related adverse events was 7.4% (5/68). Out of these five related adverse events, there was one serious adverse event (1.5%, implant site pain) at the time of database snapshot.ConclusionsThese data confirm the safety and clinical performance of the InterStim Micro device for subjects with OAB by demonstrating a significant improvement in OAB‐q HRQL score at 3‐month. Similar improvements were observed at 6 months in addition to an incidence of adverse events that is comparable to previously reported rates for SNM.

Funder

Medtronic

Publisher

Wiley

Subject

Urology,Neurology (clinical)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3