Ultra‐low‐field magnetization transfer imaging at 0.055T with low specific absorption rate

Author:

Su Shi12,Zhao Yujiao12,Ding Ye12,Lau Vick12,Xiao Linfang12,Leung Gilberto K. K.3,Lau Gary K. K.4,Huang Fan5ORCID,Vardhanabhuti Vince5,Leong Alex T. L.12,Wu Ed X.12ORCID

Affiliation:

1. Laboratory of Biomedical Imaging and Signal Processing The University of Hong Kong Hong Kong SAR China

2. Department of Electrical and Electronic Engineering The University of Hong Kong Hong Kong SAR China

3. Department of Surgery The University of Hong Kong Hong Kong SAR China

4. Department of Medicine The University of Hong Kong Hong Kong SAR China

5. Department of Diagnostic Radiology The University of Hong Kong Hong Kong SAR China

Abstract

AbstractPurposeTo demonstrate magnetization transfer (MT) effects with low specific absorption rate (SAR) on ultra‐low‐field (ULF) MRI.MethodsMT imaging was implemented by using sinc‐modulated RF pulse train (SPT) modules to provide bilateral off‐resonance irradiation. They were incorporated into 3D gradient echo (GRE) and fast spin echo (FSE) protocols on a shielding‐free 0.055T head scanner. MT effects were first verified using phantoms. Brain MT imaging was conducted in both healthy subjects and patients.ResultsMT effects were clearly observed in phantoms using six SPT modules with total flip angle 3600° at central primary saturation bands of approximate offset ±786 Hz, even in the presence of large relative B0 inhomogeneity. For brain, strong MT effects were observed in gray matter, white matter, and muscle in 3D GRE and FSE imaging using six and sixteen SPT modules with total flip angle 3600° and 9600°, respectively. Fat, cerebrospinal fluid, and blood exhibited relatively weak MT effects. MT preparation enhanced tissue contrasts in T2‐weighted and FLAIR‐like images, and improved brain lesion delineation. The estimated MT SAR was 0.0024 and 0.0008 W/kg for two protocols, respectively, which is far below the US Food and Drug Administration (FDA) limit of 3.0 W/kg.ConclusionRobust MT effects can be readily obtained at ULF with extremely low SAR, despite poor relative B0 homogeneity in ppm. This unique advantage enables flexible MT pulse design and implementation on low‐cost ULF MRI platforms to achieve strong MT effects in brain and beyond, potentially augmenting their clinical utility in the future.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3