K‐t PCA accelerated in‐plane balanced steady‐state free precession phase‐contrast (PC‐SSFP) for all‐in‐one diastolic function evaluation

Author:

Xiang Jie1ORCID,Lamy Jerome2ORCID,Qiu Maolin3,Galiana Gigi13,Peters Dana C.13ORCID

Affiliation:

1. Department of Biomedical Engineering Yale University New Haven Connecticut USA

2. Université de Paris Cardiovascular Research Center, INSERM Paris France

3. Department of Radiology and Biomedical Imaging Yale University New Haven Connecticut USA

Abstract

AbstractPurposeDiastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e′). We aimed to develop an MRI method for simultaneous all‐in‐one diastolic function evaluation in a single scan by generating a 2D phase‐contrast (PC) sequence with balanced steady‐state free precession (bSSFP) contrast (PC‐SSFP). E and A could then be measured with PC, and e′ estimated by valve tracking on the magnitude images, using an established deep learning framework.MethodsOur PC‐SSFP used in‐plane flow‐encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k‐t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC‐SSFP was compared to separate balanced SSFP cine and PC‐gradient echo acquisitions in phantoms and in 10 healthy subjects.ResultsPhantom experiments showed that PC‐SSFP measured accurate velocities compared to PC‐gradient echo (r = 0.98 for a range of pixel‐wise velocities −80 cm/s to 80 cm/s). In subjects, PC‐SSFP generated high SNR and myocardium‐blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e′ (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k‐t PCA approach processed the complex difference data and substituted in raw k‐space data. With prospective k‐t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k‐t PCA), yielding a 13% higher e′.ConclusionThe proposed PC‐SSFP method achieved all‐in‐one diastolic function evaluation.

Funder

National Institutes of Health

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3