Abstract

RationaleStable isotope analysis of O2 is a valuable tool to identify O2‐consuming processes in the environment; however, reference materials for O2 isotope analysis are lacking. Consequently, a one‐point calibration with O2 from ambient air is often applied, which can lead to substantial measurement uncertainties. Our goals were to develop a simple multipoint isotope‐ratio calibration approach and to determine measurement errors of δ18O and δ17O values of O2 associated with a one‐point calibration.MethodsWe produced O2 photosynthetically with extracted spinach thylakoids from source waters with δ18O values of −56‰ to +95‰ and δ17O values of −30‰ to +46‰. Photosynthesis was chosen because this process does not cause isotopic fractionation, so that the O isotopic composition of the produced O2 will be identical to that of the source water. The δ18O and δ17O values of the produced O2 were measured by gas chromatography coupled with isotope‐ratio mass spectrometry (GC/IRMS), applying a common one‐point calibration.ResultsLinear regressions between δ18O or δ17O values of the produced O2 and those of the corresponding source waters resulted in slopes of 0.99 ± 0.01 and 0.92 ± 0.10, respectively. In the tested δ range, a one‐point calibration thus introduced maximum errors of 0.8‰ and 3.3‰ for δ18O and δ17O, respectively. Triple oxygen isotopic measurements of O2 during consumption by Fe2+ resulted in a δ18O–δ17O relationship (λ) of 0.49 ± 0.01 without δ scale correction, slightly lower than expected for mass‐dependent O isotopic fractionation.ConclusionsNo significant bias is introduced on the δ18O scale when applying a one‐point calibration with O2 from ambient air during O2 isotope analysis. Both O2 formation and consumption experiments, however, indicate a δ17O scale compression. Consequently, δ17O values cannot be measured accurately by GC/IRMS with a one‐point calibration without determining the δ17O scale correction factor, e.g. with the O2 formation experiments described here.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

Wiley

Subject

Organic Chemistry,Spectroscopy,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3