Raw data consistent deep learning‐based field of view extension for dual‐source dual‐energy CT

Author:

Maier Joscha1,Erath Julien12,Sawall Stefan12,Fournié Eric3,Stierstorfer Karl3,Kachelrieß Marc12

Affiliation:

1. German Cancer Research Center (DKFZ) Heidelberg Germany

2. Heidelberg University Heidelberg Germany

3. Siemens Healthineers Forchheim Germany

Abstract

AbstractBackgroundDue to technical constraints, dual‐source dual‐energy CT scans may lack spectral information in the periphery of the patient.PurposeHere, we propose a deep learning‐based iterative reconstruction to recover the missing spectral information outside the field of measurement (FOM) of the second source‐detector pair.MethodsIn today's Siemens dual‐source CT systems, one source‐detector pair (referred to as A) typically has a FOM of about 50 cm, while the FOM of the other pair (referred to as B) is limited by technical constraints to a diameter of about 35 cm. As a result, dual‐energy applications are currently only available within the small FOM, limiting their use for larger patients. To derive a reconstruction at B's energy for the entire patient cross‐section, we propose a deep learning‐based iterative reconstruction. Starting with A's reconstruction as initial estimate, it employs a neural network in each iteration to refine the current estimate according to a raw data fidelity measure. Here, the corresponding mapping is trained using simulated chest, abdomen, and pelvis scans based on a data set containing 70 full body CT scans. Finally, the proposed approach is tested on simulated and measured dual‐source dual‐energy scans and compared against existing reference approaches.ResultsFor all test cases, the proposed approach was able to provide artifact‐free CT reconstructions of B for the entire patient cross‐section. Considering simulated data, the remaining error of the reconstructions is between 10 and 17 HU on average, which is about half as low as the reference approaches. A similar performance with an average error of 8 HU could be achieved for real phantom measurements.ConclusionsThe proposed approach is able to recover missing dual‐energy information for patients exceeding the small 35 cm FOM of dual‐source CT systems. Therefore, it potentially allows to extend dual‐energy applications to the entire‐patient cross section.

Funder

Siemens Healthineers

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3