Enhancing cerebral vasculature analysis with pathlength‐corrected 2D angiographic parametric imaging: A feasibility study

Author:

Shields Allison12,Williams Kyle12,Bhurwani Mohammad Mahdi Shiraz3,Setlur Nagesh Swetadri Vasan12,Chivukula Venkat Keshav4,Bednarek Daniel R.12,Rudin Stephen12,Davies Jason25,Siddiqui Adnan H.25,Ionita Ciprian N.12

Affiliation:

1. Medical Physics Program University at Buffalo Buffalo New York USA

2. Canon Stroke and Vascular Research Center University at Buffalo Buffalo New York USA

3. QAS.AI Inc Buffalo New York USA

4. Department of Biomedical Engineering Florida Institute of Technology Melbourne Florida USA

5. Department of Neurosurgery University at Buffalo Buffalo New York USA

Abstract

AbstractBackground2D angiographic parametric imaging (API) quantitatively extracts imaging biomarkers related to contrast flow and is conventionally applied to 2D digitally subtracted angiograms (DSA's). In the interventional suite, API is typically performed using 1–2 projection views and is limited by vessel overlap, foreshortening, and depth‐integration of contrast motion.PurposeThis work explores the use of a pathlength‐correction metric to overcome the limitations of 2D‐API: the primary objective was to study the effect of converting 3D contrast flow to projected contrast flow using a simulated angiographic framework created with computational fluid dynamics (CFD) simulations, thereby removing acquisition variability.MethodsThe pathlength‐correction framework was applied to in‐silico angiograms, generating a reference (i.e., ground‐truth) volumetric contrast distribution in four patient‐specific intracranial aneurysm geometries. Biplane projections of contrast flow were created from the reference volumetric contrast distributions, assuming a cone‐beam geometry. A Parker‐weighted reconstruction was performed to obtain a binary representation of the vessel structure in 3D. Standard ray tracing techniques were then used to track the intersection of a ray from the focal spot with each voxel of the reconstructed vessel wall to a pixel in the detector plane. The lengths of each ray through the 3D vessel lumen were then projected along each ray‐path to create a pathlength‐correction map, where the pixel intensity in the detector plane corresponds to the vessel width along each source‐detector ray. By dividing the projection sequences with this correction map, 2D pathlength‐corrected in‐silico angiograms were obtained. We then performed voxel‐wise (3D) API on the ground‐truth contrast distribution and compared it to pixel‐wise (2D) API, both with and without pathlength correction for each biplane view. The percentage difference (PD) between the resultant API biomarkers in each dataset were calculated within the aneurysm region of interest (ROI).ResultsIntensity‐based API parameters, such as the area under the curve (AUC) and peak height (PH), exhibited notable changes in magnitude and spatial distribution following pathlength correction: these now accurately represent conservation of mass of injected contrast media within each arterial geometry and accurately reflect regions of stagnation and recirculation in each aneurysm ROI. Improved agreement was observed between these biomarkers in the pathlength‐corrected biplane maps: the maximum PD within the aneurysm ROI is 3.3% with pathlength correction and 47.7% without pathlength correction. As expected, improved agreement with ROI‐averaged ground‐truth 3D counterparts was observed for all aneurysm geometries, particularly large aneurysms: the maximum PD for both AUC and PH was 5.8%. Temporal parameters (mean transit time, MTT, time‐to‐peak, TTP, time‐to‐arrival, TTA) remained unaffected after pathlength correction.ConclusionsThis study indicates that the values of intensity‐based API parameters obtained with conventional 2D‐API, without pathlength correction, are highly dependent on the projection orientation, and uncorrected API should be avoided for hemodynamic analysis. The proposed metric can standardize 2D API‐derived biomarkers independent of projection orientation, potentially improving the diagnostic value of all acquired 2D‐DSA's. Integration of a pathlength correction map into the imaging process can allow for improved interpretation of biomarkers in 2D space, which may lead to improved diagnostic accuracy during procedures involving the cerebral vasculature.

Funder

National Institutes of Health

Publisher

Wiley

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3