Deep learning generation of preclinical positron emission tomography (PET) images from low‐count PET with task‐based performance assessment

Author:

Dutta Kaushik12,Laforest Richard12,Luo Jingqin3,Jha Abhinav K.124,Shoghi Kooresh I.124

Affiliation:

1. Mallinckrodt Institute of Radiology Washington University School of Medicine St Louis Missouri USA

2. Imaging Science Program McKelvey School of Engineering Washington University in St Louis St Louis Missouri USA

3. Department of Surgery Public Health Sciences Washington University in St Louis St Louis Missouri USA

4. Department of Biomedical Engineering McKelvey School of Engineering Washington University in St Louis St Louis Missouri USA

Abstract

AbstractBackgroundPreclinical low‐count positron emission tomography (LC‐PET) imaging offers numerous advantages such as facilitating imaging logistics, enabling longitudinal studies of long‐ and short‐lived isotopes as well as increasing scanner throughput. However, LC‐PET is characterized by reduced photon‐count levels resulting in low signal‐to‐noise ratio (SNR), segmentation difficulties, and quantification uncertainties.PurposeWe developed and evaluated a novel deep‐learning (DL) architecture—Attention based Residual‐Dilated Net (ARD‐Net)—to generate standard‐count PET (SC‐PET) images from LC‐PET images. The performance of the ARD‐Net framework was evaluated for numerous low count realizations using fidelity‐based qualitative metrics, task‐based segmentation, and quantitative metrics.MethodPatient Derived tumor Xenograft (PDX) with tumors implanted in the mammary fat‐pad were subjected to preclinical [18F]‐Fluorodeoxyglucose (FDG)‐PET/CT imaging. SC‐PET images were derived from a 10 min static FDG‐PET acquisition, 50 min post administration of FDG, and were resampled to generate four distinct LC‐PET realizations corresponding to 10%, 5%, 1.6%, and 0.8% of SC‐PET count‐level. ARD‐Net was trained and optimized using 48 preclinical FDG‐PET datasets, while 16 datasets were utilized to assess performance. Further, the performance of ARD‐Net was benchmarked against two leading DL‐based methods (Residual UNet, RU‐Net; and Dilated Network, D‐Net) and non‐DL methods (Non‐Local Means, NLM; and Block Matching 3D Filtering, BM3D). The performance of the framework was evaluated using traditional fidelity‐based image quality metrics such as Structural Similarity Index Metric (SSIM) and Normalized Root Mean Square Error (NRMSE), as well as human observer‐based tumor segmentation performance (Dice Score and volume bias) and quantitative analysis of Standardized Uptake Value (SUV) measurements. Additionally, radiomics‐derived features were utilized as a measure of quality assurance (QA) in comparison to true SC‐PET. Finally, a performance ensemble score (EPS) was developed by integrating fidelity‐based and task‐based metrics. Concordance Correlation Coefficient (CCC) was utilized to determine concordance between measures. The non‐parametric Friedman Test with Bonferroni correction was used to compare the performance of ARD‐Net against benchmarked methods with significance at adjusted p‐value ≤0.01.ResultsARD‐Net‐generated SC‐PET images exhibited significantly better (p ≤ 0.01 post Bonferroni correction) overall image fidelity scores in terms of SSIM and NRMSE at majority of photon‐count levels compared to benchmarked DL and non‐DL methods. In terms of task‐based quantitative accuracy evaluated by SUVMean and SUVPeak, ARD‐Net exhibited less than 5% median absolute bias for SUVMean compared to true SC‐PET and lower degree of variability compared to benchmarked DL and non‐DL based methods in generating SC‐PET. Additionally, ARD‐Net‐generated SC‐PET images displayed higher degree of concordance to SC‐PET images in terms of radiomics features compared to non‐DL and other DL approaches. Finally, the ensemble score suggested that ARD‐Net exhibited significantly superior performance compared to benchmarked algorithms (p ≤ 0.01 post Bonferroni correction).ConclusionARD‐Net provides a robust framework to generate SC‐PET from LC‐PET images. ARD‐Net generated SC‐PET images exhibited superior performance compared other DL and non‐DL approaches in terms of image‐fidelity based metrics, task‐based segmentation metrics, and minimal bias in terms of task‐based quantification performance for preclinical PET imaging.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3