Breast density quantification in dual‐energy mammography using virtual anthropomorphic phantoms

Author:

Pacheco Gustavo1,Castillo‐Lopez Jorge Patricio12,Villaseñor‐Navarro Yolanda2,Brandan María‐Ester1

Affiliation:

1. Instituto de Física Universidad Nacional Autónoma de México Mexico City Mexico

2. Departamento de Imagen Instituto Nacional de Cancerología Mexico City Mexico

Abstract

AbstractPurposeBreast density is a significant risk factor for breast cancer and can impact the sensitivity of screening mammography. Area‐based breast density measurements may not provide an accurate representation of the tissue distribution, therefore volumetric breast density (VBD) measurements are preferred. Dual‐energy mammography enables volumetric measurements without additional assumptions about breast shape. In this work we evaluated the performance of a dual‐energy decomposition technique for determining VBD by applying it to virtual anthropomorphic phantoms.MethodsThe dual‐energy decomposition formalism was used to quantify VBD on simulated dual‐energy images of anthropomorphic virtual phantoms with known tissue distributions. We simulated 150 phantoms with volumes ranging from 50 to 709 mL and VBD ranging from 15% to 60%. Using these results, we validated a correction for the presence of skin and assessed the method's intrinsic bias and variability. As a proof of concept, the method was applied to 14 sets of clinical dual‐energy images, and the resulting breast densities were compared to magnetic resonance imaging (MRI) measurements.ResultsVirtual phantom VBD measurements exhibited a strong correlation (Pearson's ) with nominal values. The proposed skin correction eliminated the variability due to breast size and reduced the bias in VBD to a constant value of −2%. Disagreement between clinical VBD measurements using MRI and dual‐energy mammography was under 10%, and the difference in the distributions was statistically non‐significant. VBD measurements in both modalities had a moderate correlation (Spearman's = 0.68).ConclusionsOur results in virtual phantoms indicate that the material decomposition method can produce accurate VBD measurements if the presence of a third material (skin) is considered. The results from our proof of concept showed agreement between MRI and dual‐energy mammography VBD. Assessment of VBD using dual‐energy images could provide complementary information in dual‐energy mammography and tomosynthesis examinations.

Funder

Universidad Nacional Autónoma de México

Consejo Nacional de Ciencia y Tecnología

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3