Efficient EPID‐based quality assurance of beam time delay for respiratory‐gated radiotherapy with validation on Catalyst™ and AlignRT™ systems

Author:

Yao Kaining1,Wang Meijiao1,Du Yi12ORCID,Liu Jiacheng1,Wang Qingying2,Wang Ruoxi1,Wu Hao12,Yue Haizhen1

Affiliation:

1. Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing) Department of Radiation Oncology Peking University Cancer Hospital & Institute Beijing China

2. Institute of Medical Technology Peking University Health Science Center Beijing China

Abstract

AbstractPurposeTo propose a straightforward and time‐efficient quality assurance (QA) approach of beam time delay for respiratory‐gated radiotherapy and validate the proposed method on typical respiratory gating systems, Catalyst™ and AlignRT™.MethodsThe QA apparatus was composed of a motion platform and a Winston‐Lutz cube phantom (WL3) embedded with metal balls. The apparatus was first scanned in CT‐Sim and two types of QA plans specific for beam on and beam off time delay, respectively, were designed. Static reference images and motion testing images of the WL3 cube were acquired with EPID. By comparing the position differences of the embedded metal balls in the motion and reference images, beam time delays were determined. The proposed approach was validated on three linacs with either Catalyst™ or AlignRT™ respiratory gating systems. To investigate the impact of energy and dose rate on beam time delay, a range of QA plans with Eclipse (V15.7) were devised with varying energy and dose rates.ResultsFor all energies, the beam on time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 92.13 5.79 ms, 123.11 6.44 ms, and 303.44 4.28 ms, respectively. The beam off time delays in AlignRT™ V6.3.226, AlignRT™ V7.1.1, and Catalyst™ were 121.87 1.34 ms, 119.33 0.75 ms, and 97.69 2.02 ms, respectively. Furthermore, the beam on delays decreased slightly as dose rates increased for all gating systems, whereas the beam off delays remained unaffected.ConclusionsThe validation results demonstrate the proposed QA approach of beam time delay for respiratory‐gated radiotherapy was both reproducible and time‐efficient to practice for institutions to customize accordingly.

Funder

National Natural Science Foundation of China

National Key Research and Development Program of China

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3