Abstract

AbstractBackgroundFluoroscopic guidance has become the standard for a variety of medical procedures. Mastering these techniques requires practice, which may entail additional radiation for patients and providers. Despite their widespread use, the literature examining factors influencing radiation exposure in fluoroscopically guided pain procedures is scarce.ObjectiveTo evaluate the influence of resident involvement on radiation exposure during fluoroscopy‐guided spinal interventions.DesignSingle‐center, observational study.SettingOutpatient physiatry clinic in a teaching hospital.PatientsAll patients who received cervical or lumbar facet block(s) (FBs), transforaminal epidural steroid injection(s) (TFESIs) without digital subtraction, or a caudal epidural (CE) during the study period were included.InterventionsResident involvement in the procedures: absent, observing, or participating.Main Outcome MeasuresMachine‐indicated fluoroscopy time (seconds) and radiation dose (milligrays [mGy]).ResultsTwo hundred ninety six procedures were included: 188 FBs (58 cervical, 130 lumbar), 48 CEs, and 60 TFESIs. For lumbar FBs, fluoroscopy time and radiation dose increased significantly when residents performed them (meantime = 24.5 s, confidence interval [CI] = 20.4–28.7; meandose = 3.53 mGy, CI = 2.57–4.49) compared to when they observed (meantime = 9.9 s, CI = 8.1–11.7; meandose = 1.28 mGy, CI = 0.98–1.59) (mean difference: time = 14.63 s, CI = 9.31–19.94; dose = 2.25 mGy, CI = 1.17–3.33) and were absent during the procedure (meantime = 12.9 s, CI = 11.1–14.6; meandose = 1.65 mGy, CI = 1.40–1.89) (mean difference: time = 11.67 s, CI = 7.35–15.98; dose = 1.88 mGy, CI = 1.01–2.76). In the case of TFESIs, time, but not dose, increased significantly when residents observed (meantime = 39.1 s, CI = 30.7–47.6; meandose = 6.73 mGy, CI = 3.39–10.07) compared to when they were absent (meantime = 27.1 s, CI = 22.4–31.8; meandose = 4.41 mGy, CI = 3.06–5.76 (mean difference: time = 11.99 s, CI = 1.37–22.61; dose = 2.32 mGy, CI = −1.20–5.84). Finally, resident involvement did not significantly affect the outcomes for CEs (ptime = .032, pdose = .74) and cervical FBs (ptime = .64, pdose = .68).ConclusionResident participation affected lumbar FBs the most, with an increase in both fluoroscopy time and radiation dose.

Publisher

Wiley

Subject

Neurology (clinical),Neurology,Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3