Affiliation:
1. Department of Mechanical Engineering Guru Jambheshwar University of Science & Technology Hisar Haryana India
2. Department of Mechanical Engineering Delhi Technological University Delhi India
3. Centre for Energy and Environment Delhi Technological University Delhi India
Abstract
AbstractSolar dryers have been tested with various simple and complex design modifications for better efficiencies. This article attempts to investigate the effect of a very simple design modification on the no‐load performance of a natural convection domestic solar dryer (NCDSD). A direct‐type domestic solar dryer has been developed with an air cavity surrounding the drying chamber. To compare the effect of air cavity, a domestic solar dryer without air cavity has also been developed and both the dryers were tested simultaneously under the climate of Hisar, India. The values of thermal efficiency were calculated along with convective heat transfer coefficient from absorber plate to the drying air. Both the dryers were also analyzed by developing finite element models in COMSOL multiphysics computer software. The no‐load thermal efficiency for the domestic solar dryer without and with air cavity was found to be 22.68% and 34.08%, respectively. The values of coefficient of correlation for modeled and actual drying tray temperatures for dryer without and with air cavity were 0.980466 and 0.9833917, respectively. The proposed finite element model would be helpful in the design and development of NCDSDs.