Assessment of surface water quality near municipal Solid Waste dumping facility in Bukoba, Kagera Region, Tanzania

Author:

Lema Meserecordias W. J.1ORCID,Mwegoha William J. S.2

Affiliation:

1. Department of Environmental Engineering and Management University of Dodoma Dodoma Tanzania

2. Mzumbe University Morogoro Tanzania

Abstract

AbstractWater samples were collected from River Kanoni which passes near a municipal solid waste (MSW) dumping facility in Bukoba Town, Kagera Region, United Republic of Tanzania. The objective of the study was to assess surface water pollution caused by a MSW dump. Selected physico‐chemical parameters (pH, temperature, Electrical Conductivity [EC], and Total Dissolved Solids [TDS]), nutrient levels, as well as heavy metals concentrations (Pb, Zn, Cu, Cr, Cd) were analyzed in the laboratory at the University of Dar es Salaam, in accordance with standard methods, and were compared with the existing standard limits for freshwater qualities, as stipulated by WHO and US‐EPA. Results have shown that pH values were within the allowable range of between 6.5 and 8.5, except for one value (8.82 ± 0.11) that was measured at the midstream. Temperature values were between 26.28 ± 1.02°C and 28.35 ± 0.15°C, which are within the allowable range of between 20°C and 50°C. EC values were between 262.50 ± 8.32 μS/cm and 345.01 ± 6.48 μS/cm, which are below the maximum allowable value of 400 μS/cm. TDS values were between 183.75 ± 6.55 mg/L and 241.51 ± 11.33 mg/L, which are below the maximum allowable value of 500 mg/L. Nitrate levels were between 17.52 ± 1.12 mg/L and 32.00 ± 3.02 mg/L, which are above the standard limit of 10 mg/L above. Concentrations of Lead, Chromium, and Cadmium were between 0.03 ± 0.01 mg/L and 0.16 ± 0.05 mg/L, 0.55 ± 0.02 mg/L and 1.14 ± 0.07 mg/L, and 0.009 ± 0.12 mg/L and 0.098 ± 0.22, respectively, which are all above the recommended limits of 0.01, 0.05, and 0.003 mg/L, respectively. Values for copper and zinc were between 0.02 ± 0.12 mg/L and 0.20 ± 0.22 mg/L, and 0.79 ± 0.32 mg/L and 1.57 ± 0.04 mg/L respectively, which are below the recommended limits of 1.3 and 5 mg/L, respectively. This study has revealed that Bukoba MSW dumping facility has potential impacts on the water quality in River Kanoni, for domestic usage. This, therefore, demands all relevant authorities to immediately find a proper and sustainable replacement for the existing MSW dump in Bukoba town.

Publisher

Wiley

Subject

Management, Monitoring, Policy and Law,Public Health, Environmental and Occupational Health,Pollution,Waste Management and Disposal

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3