Quasi‐steady‐state (QUASS) reconstruction enhances T1 normalization in apparent exchange‐dependent relaxation (AREX) analysis: A reevaluation of T1 correction in quantitative CEST MRI of rodent brain tumor models

Author:

Sun Phillip Zhe123ORCID

Affiliation:

1. Department of Radiology and Imaging Sciences Emory University School of Medicine Atlanta Georgia USA

2. Winship Cancer Institute Emory University Atlanta Georgia USA

3. Primate Imaging Center, Emory National Primate Research Center Emory University Atlanta Georgia USA

Abstract

AbstractPurposeThe apparent exchange‐dependent relaxation (AREX) analysis has been proposed as an effective means to correct T1 contribution in CEST quantification. However, it has been recognized that AREX T1 correction is not straightforward if CEST scans are not performed under the equilibrium condition. Our study aimed to test if quasi‐steady‐state (QUASS) reconstruction could boost the accuracy of the AREX metric under common non‐equilibrium scan conditions.Theory and MethodsNumerical simulation and in vivo scans were performed to assess the AREX metric accuracy. The CEST signal was simulated under different relaxation delays, RF saturation amplitudes, and durations. The AREX was evaluated as a function of the bulk water T1 and labile proton concentration using the multiple linear regression model. AREX MRI was also assessed in brain tumor rodent models, with both apparent CEST scans and QUASS reconstruction.ResultsSimulation showed that the AREX calculation from apparent CEST scans, under non‐equilibrium conditions, had significant dependence on labile proton fraction ratio, RF saturation time, and T1. In comparison, QUASS‐boosted AREX depended on the labile proton fraction ratio without significant dependence on T1 and RF saturation time. Whereas the apparent (2.7 ± 0.8%) and QUASS MTR asymmetry (2.8 ± 0.8%) contrast between normal and tumor regions of interest (ROIs) were significant, the difference was small. In comparison, AREX contrast between normal and tumor ROIs calculated from the apparent CEST scan and QUASS reconstruction was 3.8 ± 1.1%/s and 4.4 ± 1.2%/s, respectively, statistically different from each other.ConclusionsAREX analysis benefits from the QUASS‐reconstructed equilibrium CEST effect for improved T1 correction and quantitative CEST analysis.

Funder

Georgia Clinical and Translational Science Alliance

Georgia Institute of Technology

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3