Validation of a clinically applicable device for fast and accurate quantification of blood volume

Author:

Breenfeldt Andersen Andreas1ORCID,Bonne Thomas C.2,Hansen Joar3,Oturai Peter4,Lundby Carsten3

Affiliation:

1. Department of Public Health, Research Unit for Exercise Biology Aarhus University Aarhus Denmark

2. Department of Nutrition, Exercise and Sport Sciences University of Copenhagen Copenhagen Denmark

3. Innland University of Applied Sciences Lillehammer Norway

4. Department of Clinical Physiology and Nuclear Medicine Rigshospitalet Copenhagen Denmark

Abstract

AbstractIntroductionDetermination of blood volume (BV) using the dual‐isotope (e.g., 99mTc‐labeled red blood cells [99mTc‐RBC] and 125I‐labeled human serum albumin [125I‐HSA]) injection method is limited in medicine due to the long isotope half‐life. However, BV has been determined in laboratory settings for 100 years using the carbon monoxide (CO)‐rebreathing‐based procedure, which allows frequent BV measurements.MethodsWe investigated the reliability and accuracy of a semi‐automated CO‐rebreathing device by comparing it against the dual‐isotope methodology and its ability to detect a known blood removal. In study A, BV was determined three times in ~2 h; twice using the device with rebreathing protocols lasting 2 (CO2min) and 10 min (CO10min) and once with the dual‐isotope technique. In study B, the accuracy of the device was assessed by its ability to detect a 2% removal of BV.ResultsA good correlation was observed between both the CO‐rebreathing protocols (r2 = 0.89–0.98; p < 0.001) and the dual‐isotope approach (r2 = 0.89–0.95; p < 0.001). In absolute terms BV was 425 ± 263 mL and 491 ± 388 mL lower (p < 0.001) when quantified with the dual‐isotope compared to the CO‐rebreathing protocols. When reducing BV by 132 ± 25 mL (2%), the device quantified a lower (p < 0.001) BV of 150 ± 45 mL.ConclusionThis study emphasizes that the semi‐automated device accurately determines small changes (i.e., 2%) in BV and that a high correlation with the dual‐isotope methodology exists. The findings are clinically relevant owing to the method's simple and fast nature (the absence of radioactive tracers and reduced time requirements, i.e., ~15 min vs. ~180 min) and the possibility for repeated measurements within a single day.

Funder

Partnership for Clean Competition

Publisher

Wiley

Subject

Microbiology (medical),Biochemistry (medical),Medical Laboratory Technology,Clinical Biochemistry,Public Health, Environmental and Occupational Health,Hematology,Immunology and Allergy

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Duplicate measures of hemoglobin mass within an hour: feasibility, reliability, and comparison of three devices in supine position;Scandinavian Journal of Clinical and Laboratory Investigation;2024-01-24

2. Determinants and reference values for blood volume and total hemoglobin mass in women and men;American Journal of Hematology;2023-11-30

3. Comment by Schmidt and Byrnes based on erroneous assumptions;Scandinavian Journal of Clinical and Laboratory Investigation;2023-07-15