Reliability of the sonographic evaluation for cervical length and elastography with pelvic parameters in term pregnancy by experienced operators with varying levels of experience

Author:

Sawaddisan Rapphon1,Khwankaew Noppasin1,Pruksanusak Ninlapa1ORCID,Suntharasaj Thitima1,Suwanrath Chikasaem1,Pranpanus Savitree1,Petpichetchian Chusana1,Suksai Manaphat1,Chainarong Natthicha1

Affiliation:

1. Department of Obstetrics and Gynecology, Faculty of Medicine Prince of Songkla University Hat Yai Thailand

Abstract

AbstractObjectiveTo assess the reliability of sonographic measurements of six cervical and pelvic parameters by three sonographers with varying levels of experience.MethodsA cross‐sectional study was conducted in pregnant women with a gestational age of ≥39 weeks. Each pregnant woman was examined by two sonographers with different levels of experience. Six parameters were measured: cervical length (CL), cervical strain elastography (extrinsic type), posterior cervical angle (PCA), fetal head‐to‐perineum distance (FHPD), fetal head‐to‐pubic symphysis distance (FHSD), and angle of progression (AOP). Intra‐ and interobserver reliabilities were assessed using the intraclass correlation coefficient with a 95% confidence interval. Pearson pairwise correlation coefficients were used to analyze the correlation between the parameter values.ResultsIn all, 66 pregnant women were enrolled in this study. We found excellent intraobserver reliability for measurements of CL, PCA, FHPD, FHSD, and AOP and good‐to‐excellent intraobserver reliability for cervical strain values in the cross‐sectional view of the endocervix in the internal os area and cross‐sectional view of the entire cervix in the internal os area. Interobserver reliability was excellent for all pelvic parameters, except for the FHPD. Strain values were moderate to excellent in the area of the internal os. A significant negative correlation between CL and strain values at the internal os was observed.ConclusionsPelvic parameters, except for FHPD, have excellent intra‐ and interobserver reliabilities. The high reproducibility of CL and cervical strain elastography at the internal os level, with a negative correlation between these two parameters, may play an important role in predicting successful induction of labor.

Funder

Faculty of Medicine, Prince of Songkla University

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3