Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D‐3D registration

Author:

Klebingat Stefan1,Bien Tanja2ORCID,Hürtgen Janine2ORCID,Grover Priyanka2,Dreischarf Marcel2,Alkhateeb Shareef3,Jäger Marcus3,Rose Georg4

Affiliation:

1. University Clinic for Neuroradiology, University Hospital Magdeburg University Clinic for Neuroradiology Magdeburg Germany

2. RAYLYTIC GmbH Department of Research & Development Leipzig Germany

3. Department of Orthopaedics, Trauma and Reconstructive Surgery St. Marien‐Hospital Mülheim an der Ruhr Germany

4. Healthcare Telematics and Medical Engineering, Institute of Medical Engineering and Research Campus STIMULATE Otto von Guericke University Magdeburg Magdeburg Germany

Abstract

AbstractThe precise and accurate measurement of implant wear, acetabular cup anteversion and inclination from routine anterior‐posterior radiographs still poses a challenge. Current approaches suffer from time‐consuming procedures accompanied by low and observer‐dependent accuracy and precision. We present and validate a novel, automated method for determining total hip arthroplasty parameters by comparing its accuracy and precision with methods in contemporary scientific literature. The algorithm uses CAD‐model‐based two dimensional‐three dimensional (2D‐3D)‐registration supported by convolutional neural networks. Two in‐vitro experimental set‐ups were designed to validate the proposed 2D‐3D‐method. The set‐ups provided 84 predefined wear values and 24 configurations of anteversion and inclination in 114 radiographs. Accuracy and precision were evaluated by systematically comparing the predefined ground truth and the automatically calculated values from in‐vitro X‐rays. In addition, an algorithm was developed and validated against physician's measurements on clinical X‐rays to determine the inclination of the interteardrop (ITL) and biischial line (BL) to account for the individual patient's pelvic rotation in the frontal plane. Using X‐rays from experimental set‐ups, the determined mean error was 0.014 mm (standard deviation: 0.020 mm; root‐mean‐square‐error: 0.024 mm) for wear in pelvic position, −0.01° (0.24°; 0.23°) for radiographic cup anteversion, and 0.11° (0.38°; 0.39°) for radiographic cup inclination. The inclination of ITL and BL was automatically determined in all clinical X‐rays with excellent interclass correlation coefficients of 0.95 and 0.91, respectively. The presented algorithm allows the accurate and precise evaluation of total hip arthroplasty parameters without additional equipment. The method might help to investigate different implant designs, biomaterials, and surgical techniques with greater objectivity.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3