Four‐Dimensional Flow MRI‐Derived Hemodynamics in Abdominal Aortic Aneurysms: Reproducibility and Associations With Diameter, Intraluminal Thrombus Volume, and Vorticity

Author:

Aalbregt Eva123ORCID,Indrakusuma Reza1,Jalalzadeh Hamid1,Planken R. Nils2ORCID,van Schuppen Joost2ORCID,Meijboom Lilian2,Balm Ron1,Nederveen Aart J.23,Yeung Kak Khee13,van Ooij Pim23

Affiliation:

1. Department of Surgery Amsterdam UMC Location Vrije Universiteit Amsterdam Amsterdam The Netherlands

2. Radiology and Nuclear Medicine Amsterdam UMC Location University of Amsterdam Amsterdam The Netherlands

3. Amsterdam Cardiovascular Sciences Amsterdam The Netherlands

Abstract

BackgroundMaximum diameter measurements are used to assess the rupture risk of abdominal aortic aneurysms (AAAs); however, these are not precise enough to predict all ruptures. Four‐dimensional (4D) flow MRI‐derived parameters provide additional information by visualizing hemodynamics in AAAs but merit further investigation before they are clinically applicable.PurposeTo assess the reproducibility of 4D flow MRI‐derived hemodynamics, to investigate possible correlations with lumen and maximum diameter, and to explore potential relationships with vorticity and aneurysm growth.Study TypeProspective single‐arm study.PopulationA total of 22 (71.5 ± 6.1 years, 20 male) asymptomatic AAA patients with a maximum diameter of at least 30 mm.Field Strength/SequenceA 3.0 T/Free‐breathing 4D flow MRI phase‐contrast acquisition with retrospective ECG‐gating.AssessmentPatients underwent two consecutive 4D flow MRI scans 1‐week apart. Aortic volumes were segmented from time‐averaged phase contrast magnetic resonance angiographies. Reproducibility was assessed by voxelwise analysis after registration. Mean flow velocity, mean wall shear stress (WSS), mean lumen diameter, and qualitative vorticity scores were assessed. In addition, Dixon MRI and retrospective surveillance data were used to study maximum diameter (including thrombus), intraluminal thrombus volume (ILT), and growth rate.Statistical TestsFor reproducibility assessment, Bland–Altman analyses, Pearson correlation, Spearman's correlation, and orthogonal regression were conducted. Potential correlations between hemodynamics and vorticity scores were assessed using linear regression. P < 0.05 was considered statistically significant.ResultsTest–retest median Pearson correlation coefficients for flow velocity and WSS were 0.85 (IQR = 0.08) m/sec and 0.82 (IQR = 0.10) Pa, respectively. Mean WSS significantly correlated with mean flow velocity (R = 0.75) and inversely correlated with mean lumen diameter (R = −0.73). No significant associations were found between 4D flow MRI‐derived hemodynamic parameters and maximum diameter (flow velocity: P = 0.98, WSS: P = 0.22).Data ConclusionA 4D flow MRI is robust for assessing the hemodynamics within AAAs. No correlations were found between hemodynamic parameters and maximum diameter, ILT volume and growth rate.Level of Evidence2Technical EfficacyStage 2

Publisher

Wiley

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3