Generating deliverable DICOM RT treatment plans for prostate VMAT by predicting MLC motion sequences with an encoder‐decoder network

Author:

Heilemann Gerd1ORCID,Zimmermann Lukas1ORCID,Schotola Raphael1,Lechner Wolfgang1ORCID,Peer Marco1ORCID,Widder Joachim1ORCID,Goldner Gregor1,Georg Dietmar1ORCID,Kuess Peter1ORCID

Affiliation:

1. Department of Radiation Oncology Comprehensive Cancer Center Vienna Medical University Vienna Vienna Austria

Abstract

AbstractBackgroundDeep learning‐based auto‐planning is an active research field; however, for some tasks a treatment planning system (TPS) is still required.PurposeTo introduce a deep learning‐based model generating deliverable DICOM RT treatment plans that can be directly irradiated by a linear accelerator (LINAC). The model was based on an encoder‐decoder network and can predict multileaf collimator (MLC) motion sequences for prostate VMAT radiotherapy.MethodsA total of 619 treatment plans from 460 patients treated for prostate cancer with single‐arc VMAT were included in this study. An encoder‐decoder network was trained using 465 clinical treatment plans and validated on 77 plans. The performance was analyzed on a separate test set of 77 treatment plans. Separate L1 losses were computed for the leaf and jaw positions as well as the monitor units, with the leaf loss being weighted by a factor of 100 before being added to the other losses. The generated treatment plans were recalculated in a treatment planning system and the dose‐volume metrics and gamma passing rates were compared to the original dose.ResultsAll generated treatment plans showed good agreement with the original data, with an average gamma passing rate (3%/3 mm) of 91.9 ± 7.1%. However, the coverage of the PTVs. was slightly lower for the generated plans (D98% = 92.9 ± 2.6%) in comparison to the original plans (D98% = 95.7 ± 2.2%). There was no significant difference in mean dose to the bladder between the predicted and original plan (Dmean of 28.0 ± 13.5 vs. 28.1 ± 13.3% of prescribed dose) or rectum (Dmean of 42.3 ± 7.4 vs. 42.6 ± 7.5%). The maximum dose to bladder was only slightly higher in the predicted plans (D2% of 100.7 ± 5.3 vs. 99.8 ± 4.0%) and for the rectum it was even lower (D2% of 100.5 ± 3.7 vs. 100.1 ± 4.3).ConclusionsThe deep learning‐based model could predict MLC motion sequences in prostate VMAT plans, eliminating the need for sequencing inside a TPS, thus revolutionizing autonomous treatment planning workflows. This research completes the loop in deep learning‐based treatment planning processes, enabling more efficient workflows for real‐time or online adaptive radiotherapy.

Publisher

Wiley

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3