New calibration setup for quantitative DCE‐US imaging protocol: Toward standardization

Author:

Hoferer Isaline12,Jourdain Laurene1,Girot Charly1ORCID,Benatsou Baya12,Leguerney Ingrid12,Cournede Paul‐Henry3,Marouf Abderahmane4,Hoarau Yannick4,Lassau Nathalie12,Pitre‐Champagnat Stephanie1

Affiliation:

1. Université Paris‐Saclay, CEA, CNRS, Inserm, BioMaps Gustave Roussy Cancer Campus Villejuif France

2. Imaging Department Gustave Roussy Cancer Campus Villejuif France

3. Université Paris‐Saclay CentraleSupélec Laboratory of Mathematics and Computer Science (MICS) Gif‐Sur‐Yvette France

4. Université de Strasbourg CNRS ICUBE UMR 7357 Strasbourg France

Abstract

AbstractBackgroundThe DCE‐US (Dynamic Contrast‐Enhanced Ultrasonography) imaging protocol predicts the vascular modifications compared with Response Evaluation Criteria in Solid Tumors (RECIST) based mainly on morphological changes. A quantitative biomarker has been validated through the DCE‐US multi‐centric study for early monitoring of the efficiency of anti‐angiogenic cancer treatments. In this context, the question of transposing the use of this biomarker to other types of ultrasound scanners, probes and settings has arisen to maintain the follow‐up of patients under anti‐angiogenic treatments. As a consequence, radiologists encounter standardization issues between the different generations of ultrasound scanners to perform quantitative imaging protocols.PurposeThe aim of this study was to develop a new calibration setup to transpose the DCE‐US imaging protocol to the new generation of ultrasound scanners using both abdominal and linear probes.MethodsThis calibration method has been designed to be easily reproducible and optimized, reducing the time required and cost incurred. It is based on an original set‐up that includes using a concentration splitter to measure the variation of the harmonic signal intensity, obtained from the Area Under the time‐intensity Curve (AUC) as a function of various contrast‐agent concentrations. The splitter provided four different concentrations simultaneously ranging from 12.5% to 100% of the initial concentration of the SonoVue contrast agent (Bracco Imaging S.p.A., Milan, Italy), therefore, measuring four AUCs in a single injection. The plot of the AUC as a function of the four contrast agent concentrations represents the intensity variation of the harmonic signal: the slope being the calibration parameter. The standardization through this method implied that both generations of ultrasound scanners had to have the same slopes to be considered as calibrated. This method was tested on two ultrasound scanners from the same manufacturer (Aplio500, Aplioi900, Canon Medical Systems, Tokyo, Japan). The Aplio500 used the settings defined by the initial multicenter DCE‐US study. The Mechanical Index (MI) and the Color Gain (CG) of the Aplioi900 have been adjusted to match those of the Aplio500. The reliability of the new setup was evaluated in terms of measurement repeatability, and reproducibility with the agreement between the measurements obtained once the two ultrasound scanners were calibrated.ResultsThe new setup provided excellent repeatability measurements with a value of 96.8%. Once the two ultrasound scanners have been calibrated for both types of probes, the reproducibility was excellent with the agreement between their respective quantitative measurement was at the lowest 95.4% and at the best 98.8%.The settings of the Aplioi900 (Canon Medical Systems) were adjusted to match those of the Aplio500 (Canon Medical Systems) and these validated settings were for the abdominal probe: MI = 0.13 and CG = 34 dB; and for the linear probe: MI = 0.10 and CG = 38 dB.ConclusionThis new calibration setup provided reliable measurements and enabled the rapid transfer and the use of the DCE‐US imaging protocol on new ultrasound scanners, thus permitting a continuation of the therapeutic evaluation of patients through quantitative imaging.

Publisher

Wiley

Subject

General Medicine

Reference34 articles.

1. Gastrointestinal Stromal Tumors Treated with Imatinib: Monitoring Response with Contrast-Enhanced Sonography

2. CEUS: Where are we in 2015?

3. Dynamic Contrast-Enhanced Ultrasound for Quantification of Tissue Perfusion

4. ErdmannDA NeyB AlatriA CalancaL Intérêt de l’échographie de contraste aux microbulles en médecine vasculaire.REVUE MÉDICALE SUISSE. Published online2016:4.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3