Quantification of water exchange across the blood‐brain barrier using noncontrast MR fingerprinting

Author:

Thomson Emma L.12ORCID,Powell Elizabeth1ORCID,Gandini Wheeler‐Kingshott Claudia A. M.234ORCID,Parker Geoff J. M.125ORCID

Affiliation:

1. Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering University College London London UK

2. NMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation UCL Queen Square Institute of Neurology, Faculty of Brain Sciences London UK

3. Department of Brain & Behavioural Sciences University of Pavia Pavia Italy

4. IRCCS Mondino Foundation Pavia Italy

5. Bioxydyn Limited Manchester UK

Abstract

AbstractPurposeA method is proposed to quantify cerebral blood volume () and intravascular water residence time () using MR fingerprinting (MRF), applied using a spoiled gradient echo sequence without the need for contrast agent.MethodsAn in silico study optimized an acquisition protocol to maximize the sensitivity of the measurement to and changes. Its accuracy in the presence of variations in , , and was evaluated. The optimized protocol (scan time of 19 min) was then tested in a exploratory healthy volunteer study (10 volunteers, mean age 24 3, six males) at 3 T with a repeat scan taken after repositioning to allow estimation of repeatability.ResultsSimulations show that assuming literature values for and , no variation in , while fitting only and , leads to large errors in quantification of and , regardless of noise levels. However, simulations also show that matching , , , and , simultaneously is feasible at clinically achievable noise levels. Across the healthy volunteers, all parameter quantifications fell within the expected literature range. In addition, the maps show good agreement between hemispheres suggesting physiologically relevant information is being extracted. Expected differences between white and gray matter (p < 0.0001) and (p < 0.0001) are observed, and show no significant differences, p = 0.4 and p = 0.6, respectively. Moderate to excellent repeatability was seen between repeat scans: mean intra‐class correlation coefficient of , , , and .ConclusionWe demonstrate that regional simultaneous quantification of , , , and using MRF is feasible in vivo.

Funder

Rosetrees Trust

Engineering and Physical Sciences Research Council

MRC

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3