High-speed digital imaging method for ciliary beat frequency measurement

Author:

Dimova Svetlana12,Maes Frederik3,Brewster Marcus E1,Jorissen Mark4,Noppe Mark1,Augustijns Patrick2

Affiliation:

1. Johnson & Johnson — Pharmaceutical Research and Development, A Division of Janssen Pharmaceutica NV, Beerse, Belgium

2. Laboratory for Pharmacotechnology and Biopharmacy, Katholieke Universiteit Leuven, Leuven, Belgium

3. Department of Electrical Engineering (ESAT/PSI) and Radiology, Katholieke Universiteit Leuven, Leuven, Belgium

4. Laboratory for Experimental Otorhinolaryngology, Katholieke Universiteit Leuven, Leuven, Belgium

Abstract

Abstract The aim of this study was to develop a high-speed digital imaging system and related software for ciliary beat frequency (CFB) analysis in order to establish an automated and reliable method that is observer independent and faster compared to the conventional computerized microscope photometry method. Using primary human nasal epithelial cell cultures, the CBF was recorded with a computerized microscope photometry system and a high-speed digital imaging system. To obtain a wide range of frequencies, glycocholate (0.5%) and chlorocresol (0.005%) were used as ciliostimulatory and cilio-inhibitory reference compounds, respectively. The mean values in hertz (± s.d.) obtained with the photometry and high-speed digital imaging systems were: controls 8.2 ± 0.9 and 7.9 ± 1.1; chlorocresol 5.0 ± 0.9 and 5.1 ± 1.1; glycocholate 9.8 ± 1.0 and 9.7 ± 0.8. A similar increase (by 20 and 24%) and decrease (by 38 and 35%) in CBF was determined by the two methods after glycocholate and chlorocresol treatment, respectively. The mean difference between the photometry and high-speed digital imaging methods was 0.2 ± 0.6 Hz, and the Bland-Altman limits of agreement were from −1.0 to + 1.4 Hz, suggesting that the results obtained by these two methods could be used interchangeably. These results show the reliability of the high-speed digital imaging system and the software developed for in-vitro CBF measurements. The advantages of the system include: (i) fast data acquisition and calculation, (ii) whole field automated CBF analysis and (iii) reduction in selection bias.

Publisher

Oxford University Press (OUP)

Subject

Pharmaceutical Science,Pharmacology

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3