A near-infrared method for the assay of cineole in eucalyptus oil as an alternative to the official BP method

Author:

Wilson Nicola D1,Watt Robert A1,Moffat Anthony C1

Affiliation:

1. Centre for Pharmaceutical Analysis, The School of Pharmacy, University of London, 29-39 Brunswick Square, London, WC1N 1AX, UK

Abstract

Abstract Eucalyptus oil of British Pharmacopoeia (BP) and European Pharmacopoeia standard must contain not less than 70.0% w/w 1,8-cineole (eucalyptol). The official assay is a freezing-point method which involves the addition of o-cresol to the eucalyptus oil, whereupon the o-cresol and the 1,8-cineole form a solid complex. The assay has several disadvantages and we aim to show that near-infrared (NIR) spectroscopy is an attractive alternative to this method, in that it is simple to use, requires no sample preparation and is potentially as accurate as the traditional method. Thirty different eucalyptus oil samples were scanned on the FOSS NIRSystems 6500 Rapid Content Sampler using a reflectance vessel as sample presentation method. The cineole content of each sample was determined by the BP method and these reference data were used to construct two calibration equations for cineole content in the oils using Vision software. The mean accuracy for the NIR method differed by 1.01% or less, and the mean bias by ±0.33% or less, compared with the BP method. Calculation of the 95% confidence intervals for the slope and intercept of plots of NIR predicted values against BP method reference values showed that there was no evidence of fixed or relative systematic errors. Tests for short-term and intermediate repeatability were conducted. The standard deviation was 0.83% w/w or less and the coefficient of variation was 1.11% or less. The confidence intervals for both short-term and intermediate repeatability overlapped with that for the BP method, suggesting that there was no evidence for a difference in values obtained by the BP and NIR methods. The range of cineole contents used in the calibrations was extended by incorporating five samples of eucalyptus oil spiked with cineole, and five samples of two essential oils known to have a lower cineole content than eucalyptus oil, to give a range of 52.5 to 99.0% w/w. The mean accuracy decreased to an error of 1.26% or less and the bias to ±0.50% or less. Again, confidence intervals suggested there was no evidence for fixed or systematic errors in the NIR calibrations. We propose that NIR spectroscopy could be used as an alternative method for the determination of cineole content in eucalyptus oils.

Publisher

Oxford University Press (OUP)

Subject

Pharmaceutical Science,Pharmacology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3