Abstract
Abstract
Eucalyptus oil of British Pharmacopoeia (BP) and European Pharmacopoeia standard must contain not less than 70.0% w/w 1,8-cineole (eucalyptol). The official assay is a freezing-point method which involves the addition of o-cresol to the eucalyptus oil, whereupon the o-cresol and the 1,8-cineole form a solid complex. The assay has several disadvantages and we aim to show that near-infrared (NIR) spectroscopy is an attractive alternative to this method, in that it is simple to use, requires no sample preparation and is potentially as accurate as the traditional method.
Thirty different eucalyptus oil samples were scanned on the FOSS NIRSystems 6500 Rapid Content Sampler using a reflectance vessel as sample presentation method. The cineole content of each sample was determined by the BP method and these reference data were used to construct two calibration equations for cineole content in the oils using Vision software. The mean accuracy for the NIR method differed by 1.01% or less, and the mean bias by ±0.33% or less, compared with the BP method. Calculation of the 95% confidence intervals for the slope and intercept of plots of NIR predicted values against BP method reference values showed that there was no evidence of fixed or relative systematic errors. Tests for short-term and intermediate repeatability were conducted. The standard deviation was 0.83% w/w or less and the coefficient of variation was 1.11% or less. The confidence intervals for both short-term and intermediate repeatability overlapped with that for the BP method, suggesting that there was no evidence for a difference in values obtained by the BP and NIR methods. The range of cineole contents used in the calibrations was extended by incorporating five samples of eucalyptus oil spiked with cineole, and five samples of two essential oils known to have a lower cineole content than eucalyptus oil, to give a range of 52.5 to 99.0% w/w. The mean accuracy decreased to an error of 1.26% or less and the bias to ±0.50% or less. Again, confidence intervals suggested there was no evidence for fixed or systematic errors in the NIR calibrations.
We propose that NIR spectroscopy could be used as an alternative method for the determination of cineole content in eucalyptus oils.
Publisher
Oxford University Press (OUP)
Subject
Pharmaceutical Science,Pharmacology
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献