Development and application of a micro-capillary rheometer for in-vitro evaluation of parenteral injectability

Author:

Allahham A1,Mainwaring D2,Stewart P1,Marriott J1

Affiliation:

1. Victorian College of Pharmacy, Monash University, Parkville, Melbourne 3052, Australia

2. Department of Applied Chemistry, Royal Melbourne Institute of Technology, Melbourne 3000, Australia

Abstract

Abstract A micro-capillary rheometer was developed to determine the rheology and injectability of parenteral formulations. The rheometer consisted of a micro-capillary and a glass syringe attached to an Instron that drove the syringe plunger at predetermined speeds and measured resulting forces on the plunger. The cross-head speed and the measured force were used to calculate the shear rate and the shear stress respectively, according to the Hagen-Poiseuille equation. The resulting rheograms of several Newtonian standards showed excellent linearity over a broad range of about 10 times 103 to 160 times 103 s−1 and produced accurate and reproducible viscosity determinations over the viscosity range of about 10 times 10−3 to 100 times 10−3 Pa.s. The developed methodology focussed primarily on the minimization of errors associated with the determination of the wall frictional force using both direct measurement and linear regression to determine this parameter from the data. The effect of micro-capillary diameter, syringe cross-sectional area and micro-capillary length was explored in an effort to increase the measured force so that wall frictional force errors could be minimized. The micro-capillary rheometer gave reproducible and accurate rheograms over a range of shear rates consistent with the shear rate range used in clinical practice, and showed that Newtonian and non-Newtonian rheological behaviours could be evaluated quantitatively.

Publisher

Oxford University Press (OUP)

Subject

Pharmaceutical Science,Pharmacology

Reference23 articles.

1. Formulation design and development of parenteral suspensions;Akers;J. Parenter. Sci. Technol.,1987

2. Corrections of dynamic and steady flow viscosities;Bagley;J. Appl. Phys.,1957

3. Separation of elastic and shear thinning effects in the capillary rheometer;Boger;Trans. Soc. Rheol.,1977

4. Observations of shear-induced particle migration for oscillatory flow of a suspension within a tube;Butler;Phys. Fluids,1999

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3