Abstract
The aim of the paper is to analyse an exemplary bolted connection under the conditions of loss of bearing capacity of some fasteners in the connection. The presented tests are numerical and concern an asymmetric bolted connection. The joined elements in the connection were modelled as 3D finite elements, and the fasteners were treated as hybrid models consisting of rigid heads and nuts, and flexible beams between them. The bolted connection was first preloaded according to six different tensioning orders using a standardised force. After
all bolts were tensioned, the selected bolts were removed, simulating bolt damage. The connection was then tested for external loads with temperatures ranging from 20 to 600°C. The influence of loosening the connection on the load in the remaining bolts at the operational
stage of the connection was investigated. The calculation results were compared with the test results for a healthy bolted connection. It was shown that the bearing capacity of the connection in the damaged state decreased by 13%.
Publisher
Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne
Subject
Industrial and Manufacturing Engineering,Safety, Risk, Reliability and Quality
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献