Left Bundle Branch Optimized Implantable Cardioverter Defibrillator (LOT-ICD) implantation in a Patient with Myotonic Dystrophy

Author:

Kara Suleyman CihanORCID,Dogan MertORCID,Canpolat UğurORCID

Abstract

Left bundle branch (LBB) optimized implantable cardioverter defibrillator (LOT-ICD) is a recently emerged alternative to the standard biventricular pacing - ICD (BiVp-ICD). The IS-1 connector pin of the ICD lead was closed with a protective cap and the LBB pacing (LBBP) lead was inserted into the ICD generator at the ventricular P/S hole. Herein, we presented a myotonic dystrophy patient who underwent LOT-ICD device implantation because of a high degree of atrioventricular block and heart failure with mid-range ejection fraction. A DDD-ICD (DF-1) was implanted in our patient which has been attached to the atrial lead (RA hole), the LBBP lead (ventricular IS-1 hole), and the ICD lead (ventricular DF-1 hole). The IS-1 pin of the ICD lead was closed accordingly. The LOT-ICD should be considered an option to standard BiVp-ICD associated with lower cost, lower procedure time, and no phrenic nerve capture.

Publisher

Pera Publishing

Reference20 articles.

1. Groh WJ, Groh MR, Saha C, Kincaid JC, Simmons Z, Ciafaloni E, Pourmand R, Otten RF, Bhakta D, Nair GV, Marashdeh MM, Zipes DP, Pascuzzi RM (2008) Electrocardiographic abnormalities and sudden death in myotonic dystrophy type 1. N Engl J Med 358:2688-2697. https://doi.org/10.1056/NEJMoa062800

2. Russo V, Capolongo A, Bottino R, Carbone A, Palladino A, Liccardo B, Nigro G, Marchel M, Golino P, D’Andrea A (2023) Echocardiographic Features of Cardiac Involvement in Myotonic Dystrophy 1: Prevalence and Prognostic Value. J Clin Med 12. https://doi.org/10.3390/jcm12051947

3. Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, Barrabes JA, Boriani G, Braunschweig F, Brignole M, Burri H, Coats AJS, Deharo JC, Delgado V, Diller GP, Israel CW, Keren A, Knops RE, Kotecha D, Leclercq C, Merkely B, Starck C, Thylen I, Tolosana JM, Group ESCSD (2021) 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J 42:3427-3520. https://doi.org/10.1093/eurheartj/ehab364

4. Chung MK, Patton KK, Lau CP, Dal Forno ARJ, Al-Khatib SM, Arora V, Birgersdotter-Green UM, Cha YM, Chung EH, Cronin EM, Curtis AB, Cygankiewicz I, Dandamudi G, Dubin AM, Ensch DP, Glotzer TV, Gold MR, Goldberger ZD, Gopinathannair R, Gorodeski EZ, Gutierrez A, Guzman JC, Huang W, Imrey PB, Indik JH, Karim S, Karpawich PP, Khaykin Y, Kiehl EL, Kron J, Kutyifa V, Link MS, Marine JE, Mullens W, Park SJ, Parkash R, Patete MF, Pathak RK, Perona CA, Rickard J, Schoenfeld MH, Seow SC, Shen WK, Shoda M, Singh JP, Slotwiner DJ, Sridhar ARM, Srivatsa UN, Stecker EC, Tanawuttiwat T, Tang WHW, Tapias CA, Tracy CM, Upadhyay GA, Varma N, Vernooy K, Vijayaraman P, Worsnick SA, Zareba W, Zeitler EP (2023) 2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure. Heart Rhythm 20:e17-e91. https://doi.org/10.1016/j.hrthm.2023.03.1538

5. Russo V, Rago A, Antonio Papa A, Nigro G (2012) Cardiac resynchronization improves heart failure in one patient with myotonic dystrophy type 1. A case report. Acta Myol 31:154-155.