The Accuracy of Different Apex Locator Systems in Detecting Root Perforations in the Presence of Different Irrigation Solutions

Author:

Çetinkaya Oğuz BurhanORCID,Çulha EmreORCID,Aydın UğurORCID

Abstract

Objective: One of the most studied topics in electronic apex locators (EALs) is the effect of root canal condition on the accuracy of EALs. In this study, the accuracy of Root ZX Mini, Raypex 6, and Apex ID in detecting root perforation was evaluated in a dry environment and in the presence of saline, ethylenediamine tetraacetic acid (EDTA), and sodium hypochlorite (NaOCl) solutions. Methods: The mesiobuccal roots of 64 human maxillary first molars were selected for the study. These root canals were perforated from buccal root surface using a #1 Freze Beutherlock Peeso to form a 0.4 mm cavity. After perforation, the area where #40 K type file appeared was recorded as the actual length (AL) and the length measured by EAL devices both in dry canals and in the presence of solutions was recorded as the electronic measurement (EL). All electronic measurements were statistically compared with the actual length. Results: All EALs achieved AL-consistent results on EL measures. Consistency was determined using Root ZX Mini measurements in dry canals and canals irrigated with saline. The consistency of EL and AL conducted with Raypex 6 and Apex ID in canals irrigated with NaOCl, saline, and EDTA was found. There was a statistically significant difference in ELs with irrigation solutions among all EALs (p<0.05). In the dry environment, there was no statistically significant difference between the EALs (p>0.05). A consistency was discovered between ELs generated with the Root ZX Mini and ALs in both dry and saline-irrigated canals. Consistency was observed between ELs measured with Raypex 6 and Apex ID and ALs in canals irrigated with NaOCl, saline, and EDTA. Conclusion: The accuracy rates of the EALs used in this research were 97%–100% in the 1 mm range and 83%–92% in the 0.5 mm range. Despite the fact that ALs and ELs differed statistically significantly at the 0.05 level, these variations weren't thought to be clinically relevant. In the presence of conditions with different electro conductors, EALs from different generations may be used safely, and in a range of canal situations, these devices can yield measurements that are most similar to the AL.

Publisher

Pera Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3