68Ga-prostate-specific membrane antigen positron emission tomography/computed tomography for patients with favorable intermediate-risk prostate cancer

Author:

Dekalo Snir,Kuten Jonathan,Campbell Jeffrey,Mintz Ishai,Bar-Yosef Yuval,Keizman Daniel,Sarid David,Even-Sapir Einat,Yossepowitch Ofer,Mano Roy

Abstract

Introduction: Current guidelines don’t support the use of pretreatment imaging in patients with favorable intermediate-risk prostate cancer. 68Ga-prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) is more accurate than conventional imaging for preoperative staging. We aimed to evaluate whether pretreatment 68Ga-PSMA PET/CT is beneficial for identifying pathological lymph node involvement (LNI) and adverse pathology among patients with favorable intermediate-risk prostate cancer. Methods: We reviewed 88 patients with favorable intermediate-risk prostate cancer who underwent 68Ga-PSMA PET/CT prior to radical prostatectomy and lymph node dissection from 2016–2020. The primary endpoint was the presence of pathological LNI. Association between pretreatment characteristics and outcomes were evaluated. Results: Preoperative 68Ga-PSMA PET/CT showed suspicious uptake in lymph nodes in 4/88 patients (5%), hence, 20 patients would need to be scanned to identify a patient with a positive lymph node on imaging. Two patients had pathological LNI, only one of whom showed 68Ga-PSMA PET/CT uptake prior to surgery. The sensitivity, specificity, positive predictive value, and negative predictive values of 68Ga-PSMA PET/CT for identifying LNI were 50%, 97%, 25%, and 99%, respectively. After surgery, four patients had evidence of prostate-specific antigen (PSA) persistence. The rate of PSA persistence was higher among patients with LNI on preoperative 68Ga-PSMA PET/CT (2/4, 50% vs. 2/84, 2%, p=0.009). Conclusions: Preoperative imaging of favorable intermediate-risk prostate cancer patients using 68Ga-PSMA PET/CT showed a low yield for identifying patients at higher risk. Consistent with current guidelines, our findings do not support the routine use of PET/CT in this group of patients. Future prospective studies are needed to validate our findings.

Publisher

Canadian Urological Association Journal

Subject

Urology,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3