Same-day trial of void and discharge following standard vs. MOSES holmium laser enucleation of the prostate: A single-center experience

Author:

Noureldin Yasser,Gupta Aurinjoy,Hodhod Amr,Zakaria Ahmed S.,Abdul Hadi Ruba,Mehrnoush Vahid,Abbas Loay,Fathy Moustafa,Alaref Amer,Kotb Ahmed,Shahrour Walid,Elmansy Hazem

Abstract

Introduction: We aimed to compare perioperative and postoperative outcomes and to assess the safety and feasibility of same-day trial of void (TOV) in patients who underwent standard holmium laser enucleation of the prostate (HoLEP) vs. MOSESTM HoLEP (MoLEP). Methods: We conducted a retrospective review of prospectively collected data of patients that underwent HoLEP (100 W) or MoLEP (120 W) with same-day catheter removal three hours postoperatively at our institution from August 2018 to September 2021. Patient demographics, intraoperative parameters, and postoperative outcomes were analyzed. Data were compared as means with standard deviation and medians with interquartile range (IQR) or numbers and percentages. Continuous and categorical variables were assessed using the Mann-Whitney U test and Chi-squared test, respectively. Predictors of shorter enucleation time and failed same-day TOV were investigated. Results: Of the 90 patients included, 28 underwent HoLEP while 62 had MoLEP. There was no significant difference between the groups in terms of the successful TOV (23 [82%] vs. 58 [93.5%], p=0.1) and readmission rate (3 [10.7%] vs. 1 [1.6%], p=0.08); however, the MoLEP group had a significantly shorter mean enucleation time (p<0.001), mean hemostasis time (p<0.001), mean morcellation time (p=0.003), and lower mean energy used (p<0.001). On the logistic regression model, MoLEP (odds ratio [OR] 0.03, 95% confidence interval [CI] 0.007–0.19, p<0.001), lower preoperative prostate-specific antigen (PSA) test (OR 1.25, 95% CI 1.01–1.55, p=0.03), and smaller prostate size (OR 1.06, 95% CI 1.02–1.09, p<0.001) were independent predictors of shorter enucleation time. History of preoperative retention was the only significant factor associated with a failed same-day TOV (p=0.04). There was no different difference in intraoperative or postoperative complication rates or postoperative functional outcomes between the two technologies. Conclusions: Same-day TOV and discharge are feasible following standard HoLEP and MoLEP, with comparable outcomes; however, the use of MOSES technology offered better enucleation efficiency with excellent hemostatic potential. Preoperative retention was the only predictor for failed same-day TOV.

Publisher

Canadian Urological Association Journal

Subject

Urology,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3