Affiliation:
1. Mechanical Engineering Department, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia
2. Consulting Services Department, Saudi Aramco, Saudi Arabia
Abstract
Boiler swing rate, which is the rate at which the boiler load is changed, has significant influence on the parameters of the boiler operating conditions such as drum water pressure and level, steam quality in the riser tubes, wall temperatures of riser tubes, and the associated thermal stresses. In this paper, the thermal stresses developed in boiler tubes due to elevated rates of heat transfer and friction are presented versus thermal stresses developed in tubes operated under normal conditions. The differential equations comprising the nonlinear model and governing the flow inside the boiler tubes were formulated to study different operational scenarios in terms of resulting dynamic response of critical variables. The experimental results and field data were obtained to validate the present nonlinear dynamic model. The calculations of the heat flux and the allowable steam quality were used to determine the maximum boiler swing rates at different conditions of riser tube of friction factor and heat flux. Diagrams for the influence of friction factor of the boiler tubes and the heat flux, that the tube is subjected to, on the maximum swing rate were examined.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献