Enabling Automated Device Size Selection for Transcatheter Aortic Valve Implantation

Author:

Astudillo Patricio12ORCID,Mortier Peter1,Bosmans Johan3,De Backer Ole4,de Jaegere Peter5,De Beule Matthieu1,Dambre Joni2

Affiliation:

1. FEops, Technologiepark-Zwijnaarde 122, Ghent, Belgium

2. Department of Electronics and Information Systems, UGent-imec, Technologiepark-Zwijnaarde 126, Ghent, Belgium

3. University Hospital Antwerp (UZA), Antwerp, Belgium

4. Department of Cardiology, Rigshospitalet University Hospital, Copenhagen, Denmark

5. Department of Cardiology, Erasmus MC, Rotterdam, Netherlands

Abstract

The number of transcatheter aortic valve implantation (TAVI) procedures is expected to increase significantly in the coming years. Improving efficiency will become essential for experienced operators performing large TAVI volumes, while new operators will require training and may benefit from accurate support. In this work, we present a fast deep learning method that can predict aortic annulus perimeter and area automatically from aortic annular plane images. We propose a method combining two deep convolutional neural networks followed by a postprocessing step. The models were trained with 355 patients using modern deep learning techniques, and the method was evaluated on another 118 patients. The method was validated against an interoperator variability study of the same 118 patients. The differences between the manually obtained aortic annulus measurements and the automatic predictions were similar to the differences between two independent observers (paired diff. of 3.3 ± 16.8 mm2 vs. 1.3 ± 21.1 mm2 for the area and a paired diff. of 0.6 ± 1.7 mm vs. 0.2 ± 2.5 mm for the perimeter). The area and perimeter were used to retrieve the suggested prosthesis sizes for the Edwards Sapien 3 and the Medtronic Evolut device retrospectively. The automatically obtained device size selections accorded well with the device sizes selected by operator 1. The total analysis time from aortic annular plane to prosthesis size was below one second. This study showed that automated TAVI device size selection using the proposed method is fast, accurate, and reproducible. Comparison with the interobserver variability has shown the reliability of the strategy, and embedding this tool based on deep learning in the preoperative planning routine has the potential to increase the efficiency while ensuring accuracy.

Funder

European Commission

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3