Affiliation:
1. Department of Medical Physics, Faculty of Medicine, Iran University of Medical Sciences (IUMS), 14155-5983 Tehran, Iran
Abstract
Ultrasound irradiation to a certain site of the body affects the efficacy of drug delivery through changes in the permeability of cell membrane. Temperature increase in irradiated area may be affected by frequency, intensity, period of ultrasound, and blood perfusion. The aim of present study is to use computer simulation and offer an appropriate model for thermal distribution profile in prostate tumor. Moreover, computer model was validated by in vivo experiments. Method. Computer simulation was performed with COMSOL software. Experiments were carried out on prostate tumor induced in nude mice (DU145 cell line originated from human prostate cancer) at frequency of 3 MHz and intensities of 0.3, 0.5, and 1 w/cm2 for 300 seconds. Results. Computer simulations showed a temperature rise of the tumor for the applied intensities of 0.3, 0.5 and 1 w/cm2 of 0.8, 0.9, and 1.1°C, respectively. The experimental data carried out at the same frequency demonstrated that temperature increase was 0.5, 0.9, and 1.4°C for the above intensities. It was noticed that temperature rise was very sharp for the first few seconds of ultrasound irradiation and then increased moderately. Conclusion. Obtained data holds great promise to develop a model which is able to predict temperature distribution profile in vivo condition.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献