Nonuniformity of Diffusing Capacity From Small Alveolar Gas Samples Is Increased in Smokers

Author:

Cotton DJ1,Mink JT1,Graham BL1

Affiliation:

1. Division of Respiratory Medicine, Department of Medicine, Royal University Hospital, University of Saskatchewan, Saskatoon, Saskatchewan, Canada

Abstract

BACKGROUND: Although centrilobular emphysema, and small airway, interstitial and alveoli inflammation can be detected pathologically in the lungs of smokers with relatively well preserved lung function, these changes are difficult to assess using available physiological tests. Because submaximal single breath washout (SBWSM) manoeuvres improve the detection of abnormalities in ventilation inhomogeneity in the lung periphery in smokers compared with traditional vital capacity manoeuvres, SBWSMmanoeuvres were used in this study to measure temporal differences in diffusing capacity using a rapid response carbon monoxide analyzer.OBJECTIVE: To determine whether abnormalities in the lung periphery can be detected in smokers with normal forced expired volumes in 1 s using the three-equation diffusing capacity (DLcoSB-3EQ) among small alveolar gas samples and whether the abnormalities correlate with increases in peripheral ventilation inhomogeneity.PARTICIPANTS AND DESIGN: Cross-sectional study in 21 smokers and 21 nonsmokers all with normal forced exhaled flow rates.METHODS: Both smokers and nonsmokers performed SBWSMmanoeuvres consisting of slow inhalation of test gas from functional residual capacity to one-half inspiratory capacity with either 0 or 10 s of breath holding and slow exhalation to residual volume (RV). They also performed conventional vital capacity single breath (SBWVC) manoeuvres consisting of slow inhalation of test gas from RV to total lung capacity and, without breath holding, slow exhalation to RV. DLcoSB-3EQ was calculated from the total alveolar gas sample. DLcoSB-3EQ was also calculated from four equal sequential, simulated aliquots of the total alveolar gas sample. DLcoSB-3EQ values from the four alveolar samples were normalized by expressing each as a percentge of DLcoSB-3EQ from the entire alveolar gas sample. An index of variation (DI) among the small-sample DLcoSB-3EQ values was correlated with the normalized phase III helium slope (Sn) and the mixing efficiency (Emix).RESULTS: For SBWSM, DIwas increased in smokers at 0 s of breath holding compared with nonsmokers, and correlated with age, smoking pack-years and Sn. The decrease in DIwith breath holding was greater in smokers and correlated with the change in Sn with breath holding. For SBWVCmanoeuvres, there were no differences due to smoking in Sn or Emix, but DIwas increased in smokers and correlated with age and smoking pack-years, but not with Sn.CONCLUSIONS: For SBWSMmanoeuvres the increase in DIin smokers correlated with breath hold time-dependent increases in Sn, suggesting that the changes in DIreflected the same structural alterations that caused increases in peripheral ventilation inhomogeneity. For SBWVCmanoeuvres, the increase in DIin smokers was not associated with changes in ventilation inhomogeneity, suggesting that the effect of smoking on DIduring this manoeuvre was due to smoke-related changes in alveolar capillary diffusion, rather than due solely to alterations in the distribution of ventilation.

Publisher

Hindawi Limited

Subject

Pulmonary and Respiratory Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3