Accuracy and Reliability of CBCT Compared to Clinical Probing in Detection of Trifurcation Defects: An In Vivo Study

Author:

Alsakr Abdulaziz Mohammad1ORCID,Creanga Adriana G.2,Alqahtani Abdullah Saad1ORCID,Gufran Khalid1ORCID

Affiliation:

1. Department of Preventive Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University Alkharj, Saudi Arabia

2. Department of Diagnostic Sciences, Rutgers School of Dental Medicine, Newark, NJ, USA

Abstract

Background. Furcation defects are areas of pathological bone resorption in multirooted teeth. The aim of the study was to compare the measurements of trifurcation bone loss, measured using CBCT, versus clinical measurements in order to evaluate the efficacy of CBCT as an adjunctive diagnostic tool. Material and Methods. The included patients had both CBCT scans for maxillary molars and completed periodontal charts. Clinical examination consisted of probing and detection of vertical and horizontal furcation defects. These were measured and recorded. CBCT measurements were then evaluated using the linear measuring tool in Carestream imaging software (Carestream, Rochester, USA) and iCAT (Imaging Sciences, Hatfield, USA). These measurements of the CBCT images were then documented and compared to clinical findings. The two examiners were blinded to each other’s measurements. Results. The most common tooth with a detected furcation defect was tooth #2 (31.7%), followed by tooth #15 (26.8%) and #3 (21.9%). The least common tooth with a detected furcation defect was #14 (19.5%). The mean values of buccal furcation for clinical and CBCT measurements were 3.01 mm and 2.6 mm, respectively. The measurements of mesial furcation were 2.5 mm and 2.2 mm for CBCT. The distal measurement of clinical examination was 2.7 mm and for CBCT was 2.44 mm. Conclusion. CBCT can be used as an adjunct to clinical furcation measurements and adds useful diagnostic information to assess trifurcation defects. In addition, CBCT limited field of view (FOV) can provide relatively high-resolution images at a reduced dose that is comparable to two-dimensional imaging.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3