Visual Performance of Eyes with Residual Refractive Errors after Implantation of an Extended Vision Intraocular Lens

Author:

Rementería-Capelo Laureano A.1,Contreras Inés123ORCID,Morán Aida1,Lorente-Hevia Pilar14,Mariñas Laura1,Ruiz-Alcocer Javier45ORCID

Affiliation:

1. Clínica Rementería, Madrid, Spain

2. Hospital Universitario Ramón y Cajal, Madrid, Spain

3. Instituto Ramón y Cajal de Investigaciones Sanitarias (IRYCIS), Madrid, Spain

4. Optics and Optometry Department, Universidad Complutense de Madrid, Madrid, Spain

5. Clinical and Experimental Eye Research Group, Universidad Complutense de Madrid, UCM 971009, Madrid, Spain

Abstract

Background. To analyze the tolerance on distance vision of different combined residual astigmatic situations in patients implanted with a novel wavefront shaping extended depth of focus (EDoF) intraocular lens (IOL). Methods. The study included patients implanted with the Acrysof® IQ Vivity® IOL. Uncorrected (UDVA) and corrected distance visual acuity (CDVA) were measured three months after surgery, considering CDVA as the reference situation of the study. Distance VA was also measured in different refractive situations: (A) with 0.50 diopters (D) of positive (myopization) and negative (hyperopization) defocus and (B) with a residual mixed astigmatic refraction induced by adding a combination of −0.25 D spherical and 0.50 D cylindrical lenses placed in vertical (against the rule-ATR), oblique, and horizontal (with the rule-WTR) positions. Results. The study included 30 eyes of 30 patients. UDVA and CDVA were −0.04 ± 0.05 and −0.05 ± 0.05 logMAR, respectively. VA values with +0.50 D and −0.50 D of defocus were 0.01 ± 0.06 and 0.00 ± 0.04 logMAR, respectively. VA was better with distance correction ( p < 0.001 ) and no differences were found between the myopic and the hyperopic situations ( p = 0.09 ). Distance VA for the ATR, oblique, and WTR astigmatic situations was 0.01 ± 0.05, 0.01 ± 0.06, and 0.01 ± 0.04 logMAR, respectively. VA was better for the reference situation ( p < 0.001 ) and no differences were found among the three astigmatic situations ( p = 0.21 ). Conclusions. Low residual defocus and mixed astigmatic errors, regardless of its orientation, seem to be tolerated by patients implanted with the studied EDoF IOL. This trial is registered with NCT05392998. Registered 26 May 2022-Retrospectively registered.

Funder

Alcon Investigator Initiated Trial

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3