Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of IOLs: A Meta-Analysis

Author:

Xu Zequan1,Li Wenzhe2,Wu Lianqun3,Xue Shuang4,Chen Xu5ORCID,Wu Qiang1ORCID

Affiliation:

1. Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, No. 600, Yishan Road, Xuhui District, Shanghai 200233, China

2. Clinical Medical College, Tianjin Medical University, No. 176, Xueyuan Road, Dagang District, Tianjin 100270, China

3. Department of Ophthalmology, Changzheng Hospital, Second Military Medical University, 415 Fengyang Road, Shanghai, 200003 Shanghai, China

4. Department of Ophthalmology, People’s Hospital of Hegang, No. 1, Dianxin Road, Gongnong District, Hegang 154100, Heilongjiang, China

5. Department of Cataract and Glaucoma, Shanghai Aier Eye Hospital, No. 1286, Hongqiao Road, Shanghai 200336, China

Abstract

Objective. To compare the clinical performance of refractive rotationally asymmetric multifocal intraocular lens (IOLs) with spherical monofocal, accommodating, and bifocal IOLs. Methods. A comprehensive literature search of PubMed, EMBASE, Cochrane Controlled Trials Register, and Web of Science up to February 2017 was performed to identify randomized controlled trials (RCT) and comparative cohort studies. Main outcomes were uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), higher-order aberrations (HOAs), MTF, Strehl ratio, and residual sphere and cylinder. Results. Mplus provided significantly worse UDVA than spherical monofocal IOLs (WMD: 0.13, P=0.008), but significantly better UIVA than high-add bifocal IOLs (WMD: −0.19, P<0.00001), spherical monofocal IOLs (WMD: −0.12, P<0.0001), and accommodating IOLs (WMD: −0.21, P<0.00001). Mplus provided significantly worse UNVA than high-add bifocal IOLs (WMD: 0.07, P<0.00001), but significantly better UNVA than spherical monofocal IOLs (WMD: −0.19, P<0.00001). Mplus resulted in significantly higher HOAs than high-add bifocal IOLs (WMD: 0.38, P<0.00001) and spherical monofocal IOLs (WMD: 0.51, P=0.0004). Mplus provided a significantly lower MTF cut-off and Strehl ratio than other type of IOLs. Conclusion. The Mplus IOLs perform best regarding intermediate visual acuity whereas they lack in distance visual acuity compared to monofocal IOLs and near visual acuity compared to bifocal IOLs. These results may be due to structure of Mplus IOLs resulting in higher-order aberrations.

Funder

Foundation of Shanghai Municipal Commission of Health and Family Planning

Publisher

Hindawi Limited

Subject

Ophthalmology