Comparison of Rhenium and Iodine as Contrast Agents in X-Ray Imaging

Author:

De La Vega José Carlos1ORCID,Esquinas Pedro Luis2ORCID,Gill Jovan Kaur1,Jessa Selin1,Gill Bradford3,Thakur Yogesh45ORCID,Saatchi Katayoun1ORCID,Häfeli Urs O.1ORCID

Affiliation:

1. Faculty of Pharmaceutical Sciences, University of British Columbia, Vancouver, British Columbia, Canada

2. Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada

3. Medical Physics Department, BC Cancer, Vancouver, British Columbia, Canada

4. Department of Radiology, University of British Columbia, Vancouver, British Columbia, Canada

5. Medical Imaging, Vancouver Coastal Health, Vancouver, British Columbia, Canada

Abstract

Purpose. The majority of X-ray contrast agents (XCA) are made with iodine, but iodine-based XCA (I-XCA) exhibit low contrast in high kVp X-rays due to iodine’s low atomic number (Z = 53) and K-edge (33.1 keV). While rhenium is a transition metal with a high atomic number (Z = 75) and K-edge (71.7 keV), the utilization of rhenium-based XCA (Re-XCA) in X-ray imaging techniques has not been studied in depth. Our study had two objectives: (1) to compare both the image quality and the absorbed dose of I- and Re-XCA and (2) to prepare and image a rhenium-doped scaffold. Procedures. I- and Re-XCA were prepared and imaged from 50 to 120 kVp by Micro-computed tomography (µCT) and digital radiography and from 120 to 220 kVp by planar X-ray imaging. The scans were repeated using 0.1 to 1.6 mm thick copper filters to harden the X-ray beam. A rhenium-doped scaffold was prepared via electrospinning, used to coat catheters, and imaged at 90 kVp by µCT. Results. I-XCA have a greater contrast-to-noise ratio (CNR) at 50 and 80 kVp, but Re-XCA have a greater CNR at >120 kVp. The difference in CNR is increased as the thickness of the copper filters is increased. For instance, the percent CNR improvement of rhenium over iodine is 14.2% with a 0.6 mm thick copper filter, but it is 59.1% with a 1.6 mm thick copper filter, as shown at 120 kVp by µCT. Upon coating them with a rhenium-doped scaffold, the catheters became radiopaque. Conclusions. Using Monte Carlo simulations, we showed that it is possible to reduce the absorbed dose of high kVp X-rays while allowing the acquisition of high-quality images. Furthermore, radiopaque catheters have the potential of enhancing the contrast during catheterizations and helping physicians to place catheters inside patients more rapidly and precisely.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging