Abstract

Adjusting generator output and cutting off load can effectively solve the problem of continuous overload and disconnection of power lines caused by power flow transfer. To suppress large-scale power outages caused by overload-dominant cascading failures, a blocking method for overload-dominant cascading failures in the power grid based on source and load collaborative regulation is proposed. The shortest path algorithm was used to identify loads and generators with shorter electrical distances from overloaded lines. Under the premise of meeting the static safety constraints of the power grid, considering the regulation of generator output and the removal of interruptible loads, a multiobjective cascading failure blocking model is established with the minimum overall control cost of the system and the minimum probability coefficient of line failure. Use the NSGA-II algorithm to solve the model and obtain the optimal plan for adjusting generator output and cutting off load. Through example verification, the proposed method can effectively alleviate the phenomenon of line overload, thereby blocking the continuation of overload-dominant cascading failures.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3