Affiliation:
1. Traffic and Transportation College, Jilin University, Changchun 130025, China
Abstract
The measurement performance of the roller tester for the vehicle brake force is evaluated by both proposed dynamic calibration and traditional static calibration to find an effective way for ensuring the vehicle safety. Three static parameters, brake force error of a single bench, difference of the left and right benches, and measurement repeatability, are verified to be eligible in the experiments. However, the experimental results of the dynamic calibration prove that the same brake tester fails on the repeatability with a 10.4% error. The dynamic calibration method improves the measurement performance of the brake tester in practical applications.
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献