Comparison of Three-Dimensional Micro-CT Angiography of Cervical Spinal Cord between Two Contrast Agents

Author:

Liu Yapu12,Liu Qi1,Yang Zhou1,Lin Junyu1,Wu Xiuhua1,Huang Zucheng1,Liu Junhao1,Li Rong1,Huang Zhiping1,Wu Xiaoliang1,Zhu Qingan1ORCID

Affiliation:

1. Department of Spinal Surgery, Nanfang Hospital, Southern Medical University, Guangzhou, China

2. Department of Spinal Surgery, Second Affiliated Hospital of Luohe Medical College, Luohe, China

Abstract

Purpose. Barium sulfate and lead oxide are commonly used for angiographic studies, but there is no report on the comparison of two contrast agents in angiography of cervical spinal cord. This study was aimed to compare the microvascular architecture of cervical spinal cord in rats after angiography with the barium sulfate agent to the lead oxide agent. Methods. Twelve adult Sprague-Dawley rats were randomly divided into the barium sulfate group (n=6) and the lead oxide group (n=6). Each rat was perfused under the same protocol using either two contrast agents. The angiography was evaluated with the vascular number at different ranks. The cervical spinal cord samples were scanned using micro-CT with low resolution and high resolution. The microvascular parameters, including ratio of vascular volume to tissue volume (VV/TV), vascular number (V.N), diameter (V.Dm), separation (V.Sp), connectivity density (Conn.D), structure model index (SMI), percentage, and volume of vessels at different diameters were measured. Results. The perfusion was better in the barium sulfate group, with more blood vessel trees of rank II and III visible compared to the lead oxide group. Low-resolution micro-CT analysis showed no difference in microvascular parameters except SMI between the two groups. High-resolution micro-CT analysis results showed that V.N and Conn.D of barium sulfate group were 60% and 290% more than those of the lead oxide group; however, V.Sp was 41% less than the lead oxide group. The percentage of vessels with diameter of 10 μm and 20 μm, and the volume of vessels with diameter of less than 100 μm was higher in the barium sulfate group than in the lead oxide group. The SMI index in the barium sulfate group was higher than that in the lead oxide group at both low resolution and high resolution. Conclusions. Compared with lead oxide, barium sulfate is more suitable for perfusion of cervical spinal cord microvessels, and cheap and nontoxic with high resolution.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Radiology Nuclear Medicine and imaging

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3