Experimental Investigation on Incorporation of Zinc-Ferrite Nanocoated Baffles for Improving the Performance of Field Power Electrical Transformer Integrated with a Solar Air Heater

Author:

Kannan Nithiyananthan1ORCID,Vasantha Gowri N.2,Muralikrishna T.2,Kumar Avinash3,Mary Anjalin F.4,Ramesh M.5ORCID,Muthuraj B.6,Birhanu Habtewolde Ababu7ORCID

Affiliation:

1. Department of Electrical Engineering, Faculty of Engineering, Rabigh King Abdulaziz University, Jeddah, Saudi Arabia

2. Department of Electrical and Electronics Engineering, Chaitanya Bharathi Institute of Technology (A), Hyderabad 500075, Telangana, India

3. Department of Electrical and Electronics Engineering, Guru Gobind Singh Educational Society’s Technical Campus, Bokaro University-Jharkhand University of Technology, Ranchi 827013, Jharkhand, India

4. Department of Physics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai 602105, Tamil Nadu, India

5. Department of Electrical and Electronic Engineering, Vaageswari College of Engineering, Karimnagar 505527, Telangana, India

6. Department of Electrical and Electronics Engineering, Panimalar Engineering College, Chennai 600123, Tamil Nadu, India

7. Faculty of Mechanical Engineering, Arba Minch Institute of Technology, Arba Minch University, P.O. Box 21, Arba Minch, Ethiopia

Abstract

Solar energy is the most accessible, eco-friendly, and renewable energy source available to meet the world’s expanding energy needs. Solar collectors are commonly utilized to convert solar energy directly into heat for purposes ranging from house heating to timber seasoning and crop drying. The purpose of this research is to design a modified solar air heater (SAH) with a baffle plate and to examine the performance due to the provision of zinc-ferrite nanocoated baffles. The entire system is mounted over a transformer for effective cooling and also produces hot air for industrial requirements. A flat plate collector and a centrifugal blower were used in the experiment. Maximum output air temperatures of 55°C, 62°C, and 72°C were measured for collectors without baffles, baffled collectors, and inverted baffled collectors, respectively. It was also found that the thermal efficiency of flat plate collectors without baffles was 36%, with baffles, it was 44%, and with inverted baffles it was 54%. This study shows that inverted SAH with zinc-ferrite nanocoated baffle plates works better than SAH without baffle plates or with baffle plates in the normal position.

Publisher

Hindawi Limited

Subject

General Engineering,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3