Left Ventricular End Diastolic Volume and Ejection Fraction Calculation: Correlation between Three Echocardiographic Methods

Author:

Benyounes Nadia1ORCID,Van Der Vynckt Clélie1,Tibi Thierry1,Iglesias Alexandra2,Gout Olivier3,Lang Sylvie4,Salomon Laurence5

Affiliation:

1. Cardiology Unit, A. de Rothschild Foundation, Paris, France

2. Alsacienne School, Paris, France

3. Department of Neurology, A. de Rothschild Foundation, Paris, France

4. Department of Cardiology, Saint-Antoine Hospital, Paris, France

5. Clinical Research Department, A. de Rothschild Foundation, Paris, France

Abstract

Background. Left ventricular ejection fraction (LVEF) and end diastolic volume (EDV) are measured using Simpson’s biplane (SB), 3-dimensional method (3DE), and speckle tracking (STE). Comparisons between methods in routine practice are limited. Our purpose was to compare and to determine the correlations between these three methods in clinical setting. Methods. LVEF and EDV were measured by three methods in 474 consecutive patients and compared using multiple Bland–Altman (BA) plots. The correlations (R) between methods were calculated. Results. Median (IQR) LVEF_SB, LVEF_STE, and LVEF_3DE were 63.0% (60–69)%, 61% (57–65)%, and 62% (57–68)%. Median (IQR) EDV_SB, EDV_STE, and EDV_3DE were 85 ml (71–106) ml, 82 ml (69–100) ml, and 73 ml (59–89) ml. R between LVEF_SB and LVEF_3DE was 0.65 when echogenicity was good and 0.43 when poor. R for EDV_SB and EDV_3DE was 0.75 when echogenicity was good and 0.45 when poor. On BA analysis, biases were acceptable (<3.5% for LVEF) but limits of agreement (LOA) were large: 95% of the differences were between −15.4% and +18.8% for LVEF as evaluated by SB in comparison with 3DE, with a bias of 1.7%. In the comparison EDV_SB and EDV_3DE, the bias was 14 ml and the LOA were between −24 ml and +53 ml. On linear regressions, LVEF_3DE = 17.92 + 0.69 LVEF_SB and EDV_3DE = 18.94 + 0.63 EDV_SB. Conclusions. The three methods were feasible and led to acceptable bias but large LOA. Although these methods are not interchangeable, our results allow 3DE value prediction from SB, the most commonly used method.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3