In Silico Pelvis and Sacroiliac Joint Motion: Refining a Model of the Human Osteoligamentous Pelvis for Assessing Physiological Load Deformation Using an Inverted Validation Approach

Author:

Ramezani Maziar1,Klima Stefan23,de la Herverie Paul Le Clerc14,Campo Jean14,Le Joncour Jean-Baptiste14,Rouquette Corentin14,Scholze Mario2,Hammer Niels235ORCID

Affiliation:

1. Auckland University of Technology, Department of Mechanical Engineering, Auckland, New Zealand

2. Department of Anatomy, University of Otago, Dunedin, New Zealand Department of Anatomy, Dunedin, New Zealand

3. Department of Trauma, Orthopedic and Plastic Surgery, University Hospital of Leipzig, Germany

4. Supméca-Institut Supérieur de Mécanique de Paris, Paris, France

5. Fraunhofer Institute for Machine Tools and Forming Technology, Dresden, Germany

Abstract

Introduction. Computational modeling of the human pelvis using the finite elements (FE) method has become increasingly important to understand the mechanisms of load distribution under both healthy and pathologically altered conditions and to develop and assess novel treatment strategies. The number of accurate and validated FE models is however small, and given models fail resembling the physiologic joint motion in particular of the sacroiliac joint. This study is aimed at using an inverted validation approach, using in vitro load deformation data to refine an existing FE model under the same mode of load application and to parametrically assess the influence of altered morphology and mechanical data on the kinematics of the model. Materials and Methods. An osteoligamentous FE model of the pelvis including the fifth lumbar vertebra was used, with highly accurate representations of ligament orientations. Material properties were altered parametrically for bone, cartilage, and ligaments, followed by changes in bone geometry (solid versus 3 and 2 mm shell) and material models (linear elastic, viscoelastic, and hyperelastic isotropic), and the effects of varying ligament fiber orientations were assessed. Results. Elastic modulus changes were more decisive in both linear elastic and viscoelastic bone, cartilage, and ligaments models, especially if shell geometries were used for the pelvic bones. Viscoelastic material properties gave more realistic results. Surprisingly little change was observed as a consequence of altering SIJ ligament orientations. Validation with in vitro experiments using cadavers showed close correlations for movements especially for 3 mm shell viscoelastic model. Discussion. This study has used an inverted validation approach to refine an existing FE model, to give realistic and accurate load deformation data of the osteoligamentous pelvis and showed which variation in the outcomes of the models are attributed to altered material properties and models. The given approach furthermore shows the value of accurate validation and of using the validation data to fine tune FE models.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3