Quantitative Analysis of Silicon Tetrachloride, Carbon Disulfide, and Dichloroethane Concentration by Raman Spectroscopy

Author:

Xiang Xiaoyan12ORCID,Shao Yufeng3,Wei Yanfang2,Xia Wentang2,Yuan Xiaoli2

Affiliation:

1. College of Communication Engineering, Chongqing University, Chongqing 400040, China

2. School of Metallurgical and Materials Engineering, Chongqing University of Science and Technology, Chongqing 401331, China

3. College of Electronic and Information Engineering, Chongqing Three Gorges University, Chongqing 404100, China

Abstract

Quantitative analysis of silicon tetrachloride, carbon disulfide, and dichloroethane concentrations to obtain vapor-liquid equilibrium data of the SiCl4-CS2 and SiCl4-C2H4Cl2 binary systems was established by Raman spectroscopy. The cheap glass sampling pipe was used as a carrier for Raman spectroscopy measurements. The Raman peak height of the internal standard was used to remove interference factors such as sampling pipe diameter, temperature, laser power, and other effects from the instrument. The peak height ratio between the Raman characteristic peak of the analyte and that of the internal standard was proportional to the analyte concentration. During the measuring process of vapor-liquid equilibrium data for the SiCl4-C2H4Cl2 binary system, the linear equation of y = 0.0068 + 0.75x with R2 of 0.9939 was used for the determination of SiCl4 concentration at the 422 cm−1 band. The linear equation of y = 0.0019 + 0.2266x with R2 of 0.9966 was used for the determination of C2H4Cl2 concentration at the 754 cm−1 band. For the SiCl4-CS2 binary system, the linear equation of y = 0.0494 + 4.7535x with R2 of 0.9962 was used for the determination of SiCl4 concentration at the 422 cm−1 band. The linear equation of y = 0.8139 + 8.7366x with R2 of 0.9973 was used for the determination of CS2 concentration at the 654 cm−1 band. The concentration of standard samples calculated by these standard curves was compared with the actual value to verify the accuracy of this method. The reproducibility is good when determining silicon tetrachloride and dichloroethane concentrations for the SiCl4-C2H4Cl2 binary system, with RSEP values of 2.81% and 2.17%, respectively. Meanwhile, the RSEP values are 3.55% and 4.16%, respectively, when determining silicon tetrachloride and carbon disulfide concentrations for the SiCl4-CS2 binary system.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3