Quantitative Approach for the Analysis of Fusional Convergence Using Eye-Tracking and SacLab Toolbox

Author:

Cercenelli Laura1ORCID,Fresina Michela2,Bortolani Barbara3ORCID,Tiberi Guido3ORCID,Giannaccare Giuseppe2ORCID,Campos E. C.2ORCID,Marcelli Emanuela3ORCID

Affiliation:

1. Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine (DIMES), Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy

2. Ophthalmology Unit, Department of Experimental Diagnostic and Specialty Medicine (DIMES), University of Bologna, S. Orsola-Malpighi Teaching Hospital, Bologna, Italy

3. Laboratory of Bioengineering, Department of Experimental Diagnostic and Specialty Medicine (DIMES), University of Bologna, Bologna, Italy

Abstract

Fusional vergence is a disjunctive movement of the eyes that is made in order to obtain single vision. The aim of the study was to provide a quantitative and objective approach for analyzing the fusional convergence response using eye tracking (ET) technology and automatic data analysis provided by the intuitive SacLab toolbox previously developed by our group. We evaluated the proposed approach in a population of 26 subjects with normal binocular vision, who were tested with base-out prisms (magnitudes 4Δ, 6Δ, and 10Δ) in order to elicit fusional convergence response. Eye movements were recorded using the Viewpoint ET and analyzed using SacLab. Parameters describing both the vergence and the version components of the fusional response (convergence duration, CD; peak convergence velocity, PCV; number of intrusive saccades, NS; and mean saccadic amplitude, MSA) were automatically calculated and provided to clinicians for an objective evaluation. Results showed that the number of subjects achieving fusional convergence decreased with prism magnitude. For subjects achieving fusion CD and PCV increased significantly (p<0.05) when increasing the prism magnitude. For NS and MSA, there were no significant changes when passing to 6Δ, but a significant increase resulted when passing to 10Δ (p<0.05). Noninvasive ET associated with the intuitive SacLab toolbox may represent a valid option to objectively characterize the fusional vergence response in clinical setting. The analysis may be extended to patients with vergence disorders.

Publisher

Hindawi Limited

Subject

Health Informatics,Biomedical Engineering,Surgery,Biotechnology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3