Patient-Specific Simulation of Coronary Artery Pressure Measurements: AnIn VivoThree-Dimensional Validation Study in Humans

Author:

Siogkas Panagiotis K.1,Papafaklis Michail I.234,Sakellarios Antonis I.1,Stefanou Kostas A.5,Bourantas Christos V.6,Athanasiou Lambros S.1,Exarchos Themis P.5,Naka Katerina K.24,Michalis Lampros K.24,Parodi Oberdan7ORCID,Fotiadis Dimitrios I.145

Affiliation:

1. Unit of Medical Technology and Intelligent Information Systems, Department of Materials Science, University of Ioannina, 45110 Ioannina, Greece

2. Department of Cardiology, Medical School, University of Ioannina, 45110 Ioannina, Greece

3. Harvard-MIT Division of Health Sciences & Technology, Massachusetts Institute of Technology, Cambridge, MA 02139, USA

4. Michailideion Cardiac Center, University of Ioannina, 45110 Ioannina, Greece

5. Biomedical Research Institute-FORTH, University of Ioannina, 45110 Ioannina, Greece

6. Thoraxcenter, Erasmus Medical Center, 3000 CA Rotterdam, Netherlands

7. Istituto di Fisiologia Clinica, Consiglio Nazionale delle Ricerche (IFC-CNR), 56124 Pisa, Italy

Abstract

Pressure measurements using finite element computations without the need of a wire could be valuable in clinical practice. Our aim was to compare the computed distal coronary pressure values with the measured values using a pressure wire, while testing the effect of different boundary conditions for the simulation. Eight coronary arteries (lumen and outer vessel wall) from six patients were reconstructed in three-dimensional (3D) space using intravascular ultrasound and biplane angiographic images. Pressure values at the distal and proximal end of the vessel and flow velocity values at the distal end were acquired with the use of a combo pressure-flow wire. The 3D lumen and wall models were discretized into finite elements; fluid structure interaction (FSI) and rigid wall simulations were performed for one cardiac cycle both with pulsatile and steady flow in separate simulations. The results showed a high correlation between the measured and the computed coronary pressure values (coefficient of determination [r2] ranging between 0.8902 and 0.9961), while the less demanding simulations using steady flow and rigid walls resulted in very small relative error. Our study demonstrates that computational assessment of coronary pressure is feasible and seems to be accurate compared to the wire-based measurements.

Funder

European Regional Development Fund

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3