Complications of Implantable Cardioverter Defibrillator and Their Potential Risk Factors in Patients with Hypertrophic Cardiomyopathy

Author:

Hedayati Goudarzi Mohammad Taghi1ORCID,Moradi Maryam2ORCID,Abrotan Saeed1ORCID,Saravi Mehrdad2ORCID,Shirafkan Hoda3ORCID,Irilouzadian Rana4ORCID,Omran Hossein Salehi1ORCID

Affiliation:

1. Cardiology Department, Rohani Hospital, School of Medicine, Babol University of Medical Sciences, Babol, Iran

2. Department of Cardiology, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran

3. Social Determinants for Health Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran

4. Burn Research Center, Iran University of Medical Sciences, Tehran, Iran

Abstract

Background. Hypertrophic cardiomyopathy (HCM) has different complications such as cardiac arrhythmia and sudden cardiac death (SCD). Insertion of an implantable cardioverter defibrillator (ICD) is recommended for HCM patients who are at high risk of SCD and malignant arrhythmias, despite having their own potential complications. Hypothesis. We aimed to investigate the prevalence of different complications of ICD insertion and the impact of the potential influential baseline characteristics in a one-year follow-up period. Methods. This was a retrospective study with a total of 71 HCM patients with ICD insertion. We evaluated the prevalence of different complications of ICD implantation and the impact of baseline characteristics on the occurrence of ICD complications using multivariate regression analysis in three 4-month periods. Results. In a one-year follow-up, 13 patients (18.3%) experienced at least one of the complications including pneumothorax, lead failure, ICD infection, inappropriate shocks, perforation, and upper limb deep vein thrombosis (DVT) with no mortality. Inappropriate shocks were reported as the most common (11.3%) complication during this period, with a gradual increase in the second (4.2%) and third (5.6%) follow-up sessions. Among all of the baseline characteristics that were investigated in this study, a positive history of hypertension was the only risk factor with significant impact on the occurrence of complications ( P  = 0.01). Conclusion. We demonstrated the occurrence of complications during a one-year follow-up as 18.3% in HCM patients with ICD insertion. A positive history of hypertension was the only baseline characteristic affecting the occurrence of complications, and inappropriate shocks were the most common complication.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3