Application of 3D-Printed Personalized Guide in Arthroscopic Ankle Arthrodesis

Author:

Duan Xiaojun1ORCID,He Peng2,Fan Huaquan1,Zhang Chengchang1,Wang Fuyou1,Yang Liu1

Affiliation:

1. Center for Joint Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing 400038, China

2. Chongqing Institute of Optics and Machines, Chongqing 401122, China

Abstract

Objective. To accurately drill the Kirschner wire with the help of the 3D-printed personalized guide and to evaluate the feasibility of the 3D technology as well as the outcome of the surgery. Methods. Patients’ DICM data of ankle via CT examinations were introduced into the MIMICS software to design the personalized guides. Two 2mm Kirschner wires were drilled with the help of the guides; the C-arm fluoroscopy was used to confirm the position of the wires before applying the cannulated screws. The patients who underwent ankle arthrodesis were divided into two groups. The experimental group adopted the 3D-printed personalized guides, while the control group received traditional method, i.e., drilling the Kirschner wires according to the surgeon’s previous experience. The times of completing drilling the Kirschner wires to correct position were compared between the two groups. Regular follow-ups were conducted to statistically analyze the differences in the ankle fusion time and AOFAS scores between the two groups. Results. 3D-printed personalized guides were successfully prepared. A total of 29 patients were enrolled, 15 in the experimental group and 14 in the control group. It took 2.2 ± 0.8 minutes to drill the Kirschner wires to correct position in the experimental group and 4.5 ± 1.6 minutes in the control group (p=0.001). No obvious complications occurred in the two groups during and after surgery. Postoperative radiographs confirmed bony fusion in all cases. There were no significant differences in the fusion time (p=0.82) and AOFAS scores at 1 year postoperatively between the two groups (p=0.55). Conclusions. The application of 3D-printed personalized guide in assisting the accurate drilling of Kirschner wire in ankle arthrodesis can shorten the operation time and reduce the intraoperative radiation. This technique does not affect the surgical outcome. Trial Registration Number. This study is registered on www.clinicaltrials.gov with NCT03626935.

Funder

Chongqing Science and Technology Commission Fund Project

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3