A General Framework for Automated Accurate Calculation of b-Matrix (Auto-b) in Diffusion MRI Pulse Sequences

Author:

Yuan Lisha1ORCID,Wu Dan1ORCID,He Hongjian1ORCID,Zhong Jianhui12ORCID

Affiliation:

1. Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou 310058, China

2. Department of Imaging Sciences, University of Rochester, Rochester 14627, USA

Abstract

To derive accurate diffusion metrics, both imaging and diffusion-sensitizing gradient pulses should be accounted for when calculating the diffusion-weighted b-matrix. However, it is complex to derive analytical solutions due to complicated interactions between gradient pulses, including orthogonal directions. This study proposes a general framework to calculate the b-matrix automatically (dubbed as Auto-b). Based on the divide-and-conquer approach, the b-matrix calculation is appropriately segmented, and the symbolic mathematical library is applied to handle integration operations for each interval. If the specifications of all gradient pulses are provided to Auto-b, an accurate b-matrix can be obtained. Three examples are explored to validate the accuracy of Auto-b and to detect b-value errors when using approximate calculations. (1) In the conventional spin-echo example, Auto-b exhibits high accuracy, as indicated by the maximum relative deviation of 1.68‰ between its calculated b-matrices and those obtained from analytical expressions. (2) Auto-b is applied to investigate the contribution of imaging gradients to the b-matrix in an optimized spin-echo echo planar imaging sequence at submillimeter resolution. Specifically, ignoring the contribution of imaging gradients results in a b-value error of 12.16 s/mm2 at the 0.8 × 0.8 × 0.8 mm3 resolution and 22.47 s/mm2 at the 0.6 × 0.6 × 0.8 mm3 resolution, respectively, when nominal b = 0. (3) Auto-b is also utilized to analyze the influence of approximate calculations in the spatiotemporally encoded sequence. The results showed that neglecting the contribution of phase-encoding blips causes large b-value errors up to 11.02 s/mm2. In addition, the rectangularization of trapezoidal waveforms led to a high relative b-value error of 39.91%. This study validates the high accuracy of Auto-b and underscores the importance of accurate b-value calculations in both submillimeter imaging and spatiotemporally encoded sequences. Attributed to its automation, accuracy, and broad applicability, Auto-b is helpful for developers of diffusion sequences.

Funder

Fundamental Research Funds for the Central Universities

Publisher

Hindawi Limited

Subject

Physical and Theoretical Chemistry,Spectroscopy,Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3