Combined Corneal Cross-Linking and Myoring Implantation in Advanced Keratoconus: Femtosecond Laser versus Manual Dissection

Author:

Ibrahim Basiony Ahmed1,Fayez ElSawy Moataz1,Mohamed Ismail Mahmoud2,Samy Abd ElAziz Mohamed1,Tawfik KhalafAllah Mahmoud1ORCID,Galal Zaky Adel1ORCID

Affiliation:

1. Department of Ophthalmology, Faculty of Medicine, Menoufia University, Menoufia, Egypt

2. Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt

Abstract

Background. Intrastromal corneal ring segments are widely adopted for keratoconus management. However, the complete ring (Myoring) was proposed to be superior in advanced cases. Myoring can be implanted either via femtoassisted or manual dissection techniques. A comparison between both techniques can delineate any differences in the outcomes. Methods. This was a prospective interventional case series study. Sixty-four eyes with progressive advanced keratoconus were enrolled: 36 and 28 had femtoassisted or manual Myoring, respectively. Uncorrected visual acuity (UCVA), corrected distance visual acuity (CDVA), maximal keratometry (Kmax), spherical equivalent (SE) and corneal thinnest location were measured in all eyes preoperatively and at one, six, and 12 months postoperatively. Epi-off corneal cross-linking (CXL) was performed eight weeks after Myoring implantation for all cases. Results. Femtoassisted Myoring dissection significantly improved UCVA and CDVA from 0.1 ± 0.06 and 0.18 ± 0.1 preoperatively to 0.29 ± 0.08 and 0.43 ± 0.1 at 12 months. Also, manual technique similarly enhanced UCVA and CDVA from 0.11 ± 0.05 and 0.2 ± 0.1 preoperatively to 0.27 ± 0.2 and 0.4 ± 0.2 at 12 months. In terms of safety, while no cases of ring extrusion were encountered with the femtoassisted technique, six (21.4%) cases of extrusion were encountered in the manual group. Conclusion. Femtoassisted or manual Myoring technique followed by CXL is an effective choice for advanced progressive keratoconus. Although it did not reach a statistical significance, the high extrusion rate with manual dissection is a red flag to be considered.

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3