Analysis of Polycyclic Aromatic Hydrocarbon in Airborne Particulate Matter Samples by Gas Chromatography in Combination with Tandem Mass Spectrometry (GC-MS/MS)

Author:

Vu-Duc Nam1ORCID,Phung Thi Lan Anh2ORCID,Le-Minh Thuy1,Nguyen Lan-Anh1,Nguyen-Thi Huong1,Pham-Thi Loan-Ha1,Doan-Thi Van-Anh1,Le-Quang Huong1,Nguyen-Xuan Hung1,Thi Nguyen Thao2,Nguyen Phuong Thanh3,Chu Dinh Binh4ORCID

Affiliation:

1. Center for Research and Technology Transfer, Vietnam Academic of Science and Technology, 18 Hoang Quoc Viet, Hanoi 100000, Vietnam

2. School of Environmental Science and Technology, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi 100000, Vietnam

3. FPT University, Hoa Lac High Tech Park, Km 29 Thang Long Boulevard, Thach That, Hanoi 100000, Vietnam

4. Department of Analytical Chemistry, School of Chemical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet Road, Hanoi 100000, Vietnam

Abstract

Polycyclic aromatic hydrocarbons (PAHs), the family of organic contaminations, have been shown to have negative effects on human health. However, until now, the comprehension on occurrence, distribution, and risk assessment of human exposure to PAHs has been limited in Vietnam. In this work, a capillary gas chromatography coupled with electron impact ionization tandem mass spectrometry (GC-EI-MS/MS) has been introduced for analysis of 16 PAHs in some particulate matter samples. PAHs have been separated on the TG 5 ms capillary gas chromatographic column and detected by tandem mass spectrometry in multiple reaction monitoring mode. The PAHs in the particulate matter (PM 2.5 and PM 10) samples were extracted by ultrasonic-assisted liquid extraction and cleaned up by an acidic silica gel solid phase extraction. The linearity range of all analyzed PAHs was from 5 to 2000 ng mL−1 with R2 ≥0.9990. Limit of detection (LOD) of PAHs in particulate matter sample was from 0.001 ng m−3 (Br-Naph) to 0.276 ng m−3 (Fln). The recovery of PAHs was investigated by international proficiency testing samples. The recoveries of PAHs in proficiency testing sample ranged from 79.3% (Chr) to 109.8% (IcdP). The in-house validated GC-EI-MS/MS method was then applied to analysis of some particulate matter samples that were collected in the Hanoi areas. The total concentrations of PAHs in several brands of samples collected from Hanoi were found in the range of 226.3 ng m−3–706.43 ng m−3. Among the studied compounds, naphthalene was found at high frequency and ranged from 106.5 ng m−3 to 631.1 ng m−3. The main distribution of the PAHs in particulate matter samples was two-ring and three-ring compounds.

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3